background image

SECTION 03

1 2

SECTION 03

Table 2 

Information requirements for electric local space heaters 

Model identifier(s): 

Item 

Symbol 

Value 

Unit  

Item 

Unit 

Heat output  

Type of heat input, for electric storage local space heaters 

only (select one) 

Nominal heat out­

put 

P

nom 

x,x 

kW  

manual heat charge control, with integrated ther­

mostat 

[yes/no] 

Minimum heat 

output (indicative) 

P

min 

[x,x/N.A.] 

kW  

manual heat charge control with room and/or 

outdoor  temperature feedback 

[yes/no] 

Maximum contin­

uous heat output 

P

max,c 

x,x 

kW  

electronic heat charge control with room and/or 

outdoor  temperature feedback 

[yes/no] 

Auxiliary electri

­

city consumption     

fan assisted heat output 

[yes/no] 

At nominal heat 

output 

el

max 

x,xxx 

kW  

Type of heat output/room temperature control (select 

one) 

At minimum heat 

output 

el

min 

x,xxx 

kW  

single stage heat output and no room tempera­

ture control 

[yes/no] 

In standby mode 

el

SB 

x,xxx 

kW  

Two or  more manual stages, no room tempera­

ture control 

[yes/no]   

with mechanic thermostat room temperature 

control 

[yes/no]   

with electronic room temperature control 

[yes/no]   

electronic room temperature control plus day 

timer 

[yes/no]   

electronic room temperature control plus week 

timer 

[yes/no]   

Other control options (multiple selections possible)   

room temperature control, with presence detec­

tion 

[yes/no]   

room temperature control, with open window 

detection 

[yes/no]   

with distance control option 

[yes/no]   

with adaptive start control 

[yes/no]   

with working time limitation 

[yes/no]   

with black bulb sensor 

[yes/no] 

Contact details 

Name and address of  the manufacturer or  its authorised representative.  

21.7.2015 

L 193/88 

Official Journal of  the European Union 

EN     

EFS0043

1.8

0.9

1.8

N/A

N/A

0

See back page 

TECHNICAL PARAMETERS

The seasonal space heating energy efficiency of all local space heaters except commercial local space heaters ηS (%):  36

Summary of Contents for Adam CO907

Page 1: ...U A L E L E C T R I C H E A T E R www adamfires co uk IMPORTANT Please be aware that this heater may take a few minutes to heat up due to the nature of the element This product is only suitable for we...

Page 2: ...to follow them could cause injury and or property damage CONTENTS SECTION 01 Cautions 03 04 Important safety information 05 07 Introduction 08 Handling 08 Unpacking 08 SECTION 02 Tools required 09 Ide...

Page 3: ...the electrical socket is accessible and located adjacent to but not above the heater Always disconnect the heater from the electrical supply before carrying out cleaning or maintenance To disconnect...

Page 4: ...he cord away from traffic areas and where it will not be tripped over Never install the heater close to curtains or combustible materials Keep furniture bedding papers clothes curtains etc at least 1m...

Page 5: ...damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard This heater must be earthed The supply cord must be safely routed from t...

Page 6: ...its service agent or similarly qualified persons in order to avoid a hazard WARNING In order to avoid overheating DO NOT COVER THE HEATER The heater must not be located immediately below a socket out...

Page 7: ...dren and vulnerable people are present This heater is hot when in use To avoid burns do not touch hot surfaces such as surfaces around the grille in front of the heater Never let bare skin touch hot s...

Page 8: ...eep the product as close to the body as possible This will prevent unnecessary and undue strain on the body Use gloves to provide additional grip Always use assistance if required UNPACKING Carefully...

Page 9: ...evel IDENTIFICATION Image for illustrative purposes only PARTS SUPPLIED Please identify the parts listed below and ensure you have ALL the correct parts before assembling the unit FIXINGS PACK 4x Shor...

Page 10: ...eat settings A switch is in the ON position when the side with the markings on i e I or II is pushed in and the LED indicator on the switch is illuminated Switch 1 I provides 500W heat output Switch 2...

Page 11: ...neous material that may be drawn into the appliance which could affect its performance S E C T I O N 0 3 1 1 S E C T I O N 0 3 THERMOSTAT The thermostat is designed to maintain a comfortable room temp...

Page 12: ...stage heat output and no room tempera ture control yes no In standby mode elSB x xxx kW Two or more manual stages no room tempera ture control yes no with mechanic thermostat room temperature control...

Page 13: ...not correspond with the markings identifying the terminals in your plug proceed as follows The green and yellow earth wire must be connected to the terminal in the plug which is marked with the lette...

Page 14: ...electrical products sold within the European Community This appliance is labelled in accordance with European Directive 2002 96 EC concerning Waste Electrical and Electronic Equipment WEEE Waste elect...

Page 15: ...S E C T I O N 0 3 1 5 S E C T I O N 0 3...

Page 16: ...has been misused transformed modified or altered in any way If your product fails within the guarantee period please ensure that you have all necessary documentation available including proof or purc...