TESTING AND COMMISSIONING

Turn on and test the gas supply up to the fire for any leaks, in accordance with the current edition of
BS6891.

OPERATING THE APPLIANCE

The pilot is visible behind the left hand side of the burner.

The control knob is located on the lower right hand side of the
outer case. It is of a spherical design and is marked as shown in
the diagram to the right;

Push in and turn the control knob to the SPARK position, and hold
there for a few seconds. Continue turning anti-clockwise through
the spark click to the PILOT light position, ensuring the pilot has
lit. If not, return the knob clockwise, and repeat.

When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds. Now release the knob and the pilot
should stay alight. If the pilot is extinguished during use, wait
three minutes before repeating the ignition procedure. 

To achieve the HIGH setting, push the control knob in slightly and
continue turning anti-clockwise to the high position. The main
burner should light after a few seconds.  To decrease the setting to LOW, turn the control knob clockwise
to the low setting.

To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the
pilot position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and
release.

SPARK FAILURE 

The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good spark.  There
should be no need to adjust this.  If under any circumstances the piezo electric spark fails, the pilot can-
not be lit manually.

SETTING PRESSURE

The pressure test point is located on the left hand side of the appliance, on the main burner pipe, next to
the brass restrictor/connector. Release the setting pressure test point screw, and attach a U gauge. Light
the fire on the HIGH setting.

To commission the appliance, the burner pressure must be in accordance with the figures stated in the data
section of these instructions. 

The fire is factory set to achieve these pressures and
any significant variation could indicate a supply prob-
lem. If the pressure is too high, the gas supply meter
may be set incorrectly.  This should be checked with
the fire running and if necessary reset by the gas sup-
plier.

If the burner pressure is too low, then check the inlet
pressure with the appliance running.  If this is less
than approximately 20mbar it will need to be reset by
the gas supplier. If the setting pressure is too low, but
the meter pressure is acceptable, then a problem in
the supply pipework is to be suspected.  

This will be dirt and debris, kinked or inadequate size pipes, restriction in a fitting, shut off elbow not fully
open or solder flashing across a joint. Identify the cause of the restriction and rectify. Switch the fire off,
disconnect the U gauge and refit the test nipple screw. Light the fire and check for gas soundness. 

In the event that the burner pressure is not in accordance with the figures stated in the data section of these
instructions, the appliance must not be commissioned, and the manufacturer should be contacted for guid-
ance.

6

8.3

8.0

8.1

8.2

‘OFF’ position

‘SPARK’ position

‘LOW’ position

‘HIGH’ position

Summary of Contents for L23G

Page 1: ...EL LE ES SS S G GA AS S F FI IR RE E M MO OD DE EL L L L2 23 3G G I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D U US SE ER R I IN NS ST TR RU UC CT TI IO ON NS S All instructions must be handed to u...

Page 2: ...FL05 FL06...

Page 3: ...d by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room vol ume in ft3 by 35 3 This appliance is intended as a secondary source of heat only and should not be used in a...

Page 4: ...only in a suffi ciently ventilated space A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibilit...

Page 5: ...a home however there are exceptions and the appliance may not be used in the following rooms Bedrooms or areas which are mainly used for sleeping Bathrooms or areas where large amounts of steam are l...

Page 6: ...positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positi...

Page 7: ...e gas supply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas connections may be made using the entry points at either end of the firebox or the on...

Page 8: ...tely 5mm from the wall Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance Insert the lower fixing screws into the lower wall plugs through...

Page 9: ...f under any circumstances the piezo electric spark fails the pilot can not be lit manually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burner...

Page 10: ...n in order to create a 2mm gap shown Simply hang the facia panel onto the outer casing ensuring that the corresponding keyhole shaped holes engage the screw heads fully BRIEFING THE CUSTOMER All instr...

Page 11: ...main burner pipes and blow through to dislodge any debris Now remove the restric tor elbow and blow through to make sure it is entirely clear Unclip the pilot lint gauze and clean with a soft brush Cl...

Page 12: ...gure by 10 000 Examples 35ppm 0 0035 15ppm 0 0015 5ppm 0 0005 Now divide the concentration of carbon monoxide CO expressed in percent by the concentration of car bon dioxide CO2 to obtain the applianc...

Page 13: ...tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If th...

Page 14: ...bracket Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See...

Page 15: ...or discolouration may occur over time The appliance must not be positioned vertically within 100 mm of a carpeted floor rugs or fabric materi als of any kind This dimension is measured vertically to t...

Page 16: ...or or window has been opened cre ating a draught then pilot disturbance could be the problem and removal of the draught should resolve this The appliance can then be re lit in accordance with the prev...

Reviews: