It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing
procedures. The expected life of the catalysts is in excess of 11,000 hours (10 years of normal use). After
this time the catalysts should be replaced.

If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vac-
uum cleaner. If removed for cleaning ensure the seals are in good condition before replacing the catalyst.
New seals will usually be required.

The performance of the catalysts may be checked using a combustion gas analyser as follows. Any analyser
used should conform to BS7927 : 1998 + A1 : 1999.

Ignite the fire as per the operating instructions, and run at maximum setting for 15 minutes. Position gas
sample probe directly over the catalysts via the outlet grille, on top of the appliance. Record the carbon
dioxide (CO2) concentration and then the carbon monoxide (CO) concentration as displayed by the analyser
- also noting the units in which the values are expressed. 

Most analysers display carbon dioxide (CO2) concentrations in percentage (%) terms and carbon monoxide
concentration in parts per million (ppm) terms.

In order to calculate the combustion ratio for the appliance (CO/CO2) it is first necessary to express both
gas concentrations in terms of percentage. To convert from parts per million (ppm) to a percentage (%)
divide the ppm figure by 10,000. Examples : 35ppm = 0.0035%, 15ppm = 0.0015%, 5ppm = 0.0005%.

Now divide the concentration of carbon monoxide (CO) expressed in percent by the concentration of car-
bon dioxide (CO2) to obtain the appliance combustion ratio.

The combustion ratio of the gasses emitted by the catalytic convertor should not exceed 0.0015.

If replacing, firstly, remove the decorative frame/glass facia as described in section 8.4. The catalysts are
located on the top of the internal firebox and can be removed be unscrewing the retaining nuts securing
the clamping plates. Remove the catalysts their seals and discard. Refit the new catalysts and seals in
reverse order, ensure the catalysts and the glass door have good seals. 

TESTING FOR FIREBOX LEAKAGE

Appliances that are several years old or have been extensively dismantled should be checked for sound-
ness. It is important that all the products of combustion pass through the catalytic converter at the top of
the firebox before leaving the appliance. 

The firebox is heated by lighting for a few minutes to provide a flow through the firebox. The burner is
then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray.
Large quantities of smoke will emerge from the top of the appliance, but none should emerge from the
joints or gasket faces, especially around the door. 

It is important to note that the appliance can never be expected to be 100% smoke tight and small quan-
tities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the
fire is in operation.

9

CO (%)
CO2 (%) = ratio

10.4

10.3

Summary of Contents for L23G

Page 1: ...EL LE ES SS S G GA AS S F FI IR RE E M MO OD DE EL L L L2 23 3G G I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D U US SE ER R I IN NS ST TR RU UC CT TI IO ON NS S All instructions must be handed to u...

Page 2: ...FL05 FL06...

Page 3: ...d by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room vol ume in ft3 by 35 3 This appliance is intended as a secondary source of heat only and should not be used in a...

Page 4: ...only in a suffi ciently ventilated space A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibilit...

Page 5: ...a home however there are exceptions and the appliance may not be used in the following rooms Bedrooms or areas which are mainly used for sleeping Bathrooms or areas where large amounts of steam are l...

Page 6: ...positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positi...

Page 7: ...e gas supply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas connections may be made using the entry points at either end of the firebox or the on...

Page 8: ...tely 5mm from the wall Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance Insert the lower fixing screws into the lower wall plugs through...

Page 9: ...f under any circumstances the piezo electric spark fails the pilot can not be lit manually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burner...

Page 10: ...n in order to create a 2mm gap shown Simply hang the facia panel onto the outer casing ensuring that the corresponding keyhole shaped holes engage the screw heads fully BRIEFING THE CUSTOMER All instr...

Page 11: ...main burner pipes and blow through to dislodge any debris Now remove the restric tor elbow and blow through to make sure it is entirely clear Unclip the pilot lint gauze and clean with a soft brush Cl...

Page 12: ...gure by 10 000 Examples 35ppm 0 0035 15ppm 0 0015 5ppm 0 0005 Now divide the concentration of carbon monoxide CO expressed in percent by the concentration of car bon dioxide CO2 to obtain the applianc...

Page 13: ...tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If th...

Page 14: ...bracket Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See...

Page 15: ...or discolouration may occur over time The appliance must not be positioned vertically within 100 mm of a carpeted floor rugs or fabric materi als of any kind This dimension is measured vertically to t...