In the Event of an Alarm 
 

1.

 

Immediately shutdown all engines, powered ventilation, and electrical systems. 

2.

 

Extinguish all smoking materials. 

3.

 

DO NOT open the engine compartment. 

4.

 

Before inspecting for damage, allow the agent to “soak” the compartment for at least 

15 minutes and wait for hot metals or fuels to cool.  

5.

 

Have approved portable extinguishers in hand and ready for use. 

6.

 

Do not breathe fumes or vapors caused by the fire and/or suppression agent. They are 
hazardous and toxic. Refer to Health and Safety section of the Extinguisher Manual. 

7.

 

Forced ventilation will often be necessary. Care should be taken to readily dissipate 
hazardous atmospheres and not merely move them to another location. Consideration 
should be given to exhaust paths when opening or venting the enclosure after 
discharge. Ventilation should not be directed near any area that might be used as a 
gathering spot for personnel.

 

 

Repairing Fireboy Deluxe Discharge Alarm(s) 
 
Fireboy Deluxe Discharge Alarms are not field serviceable.  Components must be returned to the 
factory for any repairs. 
 
 
Returning Fireboy Deluxe Discharge Alarm(s) 
 
No product may be returned for credit or repair wit

hout a written “Returned Material 

Authorization” (RMA) form.  Purchaser must call or email Fireboy

-Xintex 616-735-9380 or 

[email protected] for a RMA.  If due to extenuating circumstances a product is to be 
returned, after approval it must be received in 100% new/resalable condition.  Products stored by 
the buyer for more than 26 weeks may not be returned for any reason.  Maintaining fresh and 
current inventory is the responsibility of the buyer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DU-RBH-01

Page 1: ...Deluxe Discharge Alarm DU RBH 01 Round Black Horn DU RCH 01 Round Chrome Horn Owner s Manual Installation Instructions Read and comply with all instructions warnings and limitations before installing...

Page 2: ...thout notice General Information 3 Specifications 3 Operation of Fireboy Deluxe Discharge Alarm s 3 Installation 5 Installing the Display Unit DU RBH 01 DU RCH 01 5 Electrical Connections DU RBH 01 DU...

Page 3: ...pecifications DU RBH 01 DU RCH 01 Operating Voltage 9 30 VDC Nominal Current Draw 25mA 12 VDC Maximum Current Draw 75mA 9 VDC Operating Temperature 22 F 6 C to 158 F 70 C Alarm Horn 68dB Operation of...

Page 4: ...4 Part Number 18146 D 08 01 2018 DU RBH 01 DU RCH 01 YELLOW Pressure Switch Input Fireboy Fire Extinguisher Pressure Switch RED Power BLACK Ground Ground 1 0 Amp Fuse...

Page 5: ...g to the power source Connect the Red wire to Power with an inline 1 0 Amp fuse Connect the Black wire to Ground A Yellow 16 GA wire is provided for connecting the Deluxe Discharge Alarm to a Fireboy...

Page 6: ...other location Consideration should be given to exhaust paths when opening or venting the enclosure after discharge Ventilation should not be directed near any area that might be used as a gathering s...

Page 7: ...ent of Fireboy Xintex LLC does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation of the product or any other incidental co...

Reviews: