Fireboy- Xintex DU-RBH-01 Owner'S Manual & Installation Instructions Download Page 3

Part Number

 

18146, D, 08/01/2018

 

 

General Information 
 
The DU-RBH-01 and DU-RCH-01 Deluxe Discharge Alarms are an effective means to monitor the 
status of your Fireboy Pre-engineered Fire Suppression system.  The Deluxe Discharge Alarms 
have both visual and audible indication of the Fire Suppression system

’s status

.   

 
 
Specification 
 
System Specifications (DU-RBH-01/DU-RCH-01) 
Operating Voltage: 9-30 VDC 
Nominal Current Draw: 25mA @ 12 VDC 
Maximum Current Draw: 75mA @ 9 VDC 
Operating Temperature: 22°F (-6°C) to 158°F (70°C) 

Alarm Horn: ≈ 6

8dB 

 
 

Operation of Fireboy Deluxe Discharge Alarm(s) 

 

The Deluxe Discharge Alarm has a Green LED located on the front face of the unit.  The LED will be 
illuminated as long as the Fire Suppression bottle is full.  If the Fire Suppression bottle drops in 
pressure from either a discharge or leak, the LED will turn off, and the horn will sound. 
 

 
 
 
 
 
 

DU-RBH-01 
DU-RCH-01 

 

Summary of Contents for DU-RBH-01

Page 1: ...Deluxe Discharge Alarm DU RBH 01 Round Black Horn DU RCH 01 Round Chrome Horn Owner s Manual Installation Instructions Read and comply with all instructions warnings and limitations before installing...

Page 2: ...thout notice General Information 3 Specifications 3 Operation of Fireboy Deluxe Discharge Alarm s 3 Installation 5 Installing the Display Unit DU RBH 01 DU RCH 01 5 Electrical Connections DU RBH 01 DU...

Page 3: ...pecifications DU RBH 01 DU RCH 01 Operating Voltage 9 30 VDC Nominal Current Draw 25mA 12 VDC Maximum Current Draw 75mA 9 VDC Operating Temperature 22 F 6 C to 158 F 70 C Alarm Horn 68dB Operation of...

Page 4: ...4 Part Number 18146 D 08 01 2018 DU RBH 01 DU RCH 01 YELLOW Pressure Switch Input Fireboy Fire Extinguisher Pressure Switch RED Power BLACK Ground Ground 1 0 Amp Fuse...

Page 5: ...g to the power source Connect the Red wire to Power with an inline 1 0 Amp fuse Connect the Black wire to Ground A Yellow 16 GA wire is provided for connecting the Deluxe Discharge Alarm to a Fireboy...

Page 6: ...other location Consideration should be given to exhaust paths when opening or venting the enclosure after discharge Ventilation should not be directed near any area that might be used as a gathering s...

Page 7: ...ent of Fireboy Xintex LLC does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation of the product or any other incidental co...

Reviews: