2.3 TECHNICAL SPECIFICATIONS - SLIMLINE SYSTEMPAC BOILER
Model
Enviromax
Output
kW
Weight
kg
Dimensions
H
W
D
A
I
J
Slimline Systempac C26
20-26
150
920
465
760
794
277
126
Slimline Systempac C35
26-35
153
920
465
760
794
277
126
H
W
D
J
I
J
A
Boiler Model
C26
C35
Heat Output kW
20-26
26-35
Max. BTU/h (‘000)
70-90
90-120
CONNECTIONS
Heating Flow
22 mm dia.
28 mm dia.
Heating Return
1” BSP
1” BSP
Mains Cold Feed (Copper)
15 mm dia.
15 mm dia.
Hot Water Delivery (Copper)
-
-
Drain Off Valve
1
/
2
” BSP
1
/
2
” BSP
Safety Pressure Valve Outlet (Copper)
15 mm dia.
15 mm dia.
Condensate Trap
22 mm dia. plastic
22 mm dia. plastic
CIRCULATING PUMP
25/60
25/60
Integral Expansion Vessel Normal Capacity
12 litres
12 litres
Expansion Vessel Pre-charge Pressure
1 bar
1 bar
Low Pressure Water Switch?
Filling Loop Included?
WATER CONTENT
Boiler
24 litres
24 litres
Primary Tank
-
-
FLUE
Integral Flue
Integral Flue
HEATING SYSTEM (SEALED)
Fit in accordance with BS 7074 Part 1, BS 5449, OFTEC standards and all other relevant legislation.
Max. Operating Pressure
2.5 bar
Max. System Pressure Cold
1.5 bar
Min. System Pressure Cold
0.5 bar
Preset Pressure Relief Valve
3 bar
MAINS WATER SUPPLY PRESSURE
Min. 1 bar - Max. 10 bar (for user comfort, we recommend pressure at tap to be between 2 and 5 bar).
Limescale excess: When over 150/200 ppm, fit appropriate scale reducer.
WATER SIDE RESISTANCE
20kW
26kW
35kW
Flow Rate To Give A Nominal Output At 10K Differential
Flow Rate Measured
1642 kg/h
2135 kg/h
2874 kg/h
Waterside Resistance
0.18 mbar
0.18 mbar
0.18 mbar
Flow Rate To Give A Nominal Output At 20K Differential
Flow Rate Measured
870 kg/h
1131 kg/h
1523 kg/h
Waterside Resistance
0.19 mbar
0.19 mbar
0.19 mbar
PRESSURE JET OIL BURNERS
Riello RDB 2.2 R
FUEL
Diesel 35 Second Gas Oil
ELECTRICAL SUPPLY
230V AC 50Hz 5A
TEMPERATURE CONTROL
Boiler Central Heating Control
60˚C - 80˚C
Boiler Safety Limit
110˚C
Over-run - Fixed
87˚C
Use of copper pipe is recommended for a minimum of 1 metre off the boiler.