3
4.0 INSTALLATION INSTRUCTION
4.1 PERFORMANCE
The following highlights the output and test performance of the inset stove:
Fuel Type
Wood
Ancit
Ancit
Output to Water - kW
7.3
8.3
7.2
Output to Space - kW
2.5
3.6
0.2
Efficiency - %
75.0
79.9
81.5
CO (@13% O
2
)
0.61
0.36
0.44
BS Standard
BS EN 13229:2001
Test Type
Intermittent
Intermittent
Continuous
Maximum water operating pressure: 3 bar. Minimum safe distance from
combustible materials: sides 75mm and shelf 200mm.
Fuel Type
Wood
Ancit
Ancit
Output to Water - kW
6.9
12.1
7.1
Output to Space - kW
2.6
3.6
1.7
Efficiency - %
77.0
81.0
79.6
CO (@13% O
2
)
0.91
0.43
0.41
BS Standard
BS EN 13229:2001
Test Type
Intermittent
Intermittent
Continuous
Maximum water operating pressure: 3 bar. Minimum safe distance from
combustible materials: sides 75mm and shelf 200mm.
Heat outputs and efficiencies are based on heat over a one hour period, using Ancit solid
fuel. Outputs are obtained by independent testing to BS Standard EN 13229, burning Ancit
solid fuel.
The appliance is capable of intermittent operation when burning wood logs and both
intermittent and continuous operation when burning smokeless fuel.