Page 2: ...09 for further information Battery powered Alarm Control Unit with Test Silence Locate function Non replaceable 3V DC battery W2 module contained within WTSL SN 1 independently tested to RF standard EN 301 489 1 V1 9 2 EN 301 489 3 V1 6 1 EN 300 220 2 V3 1 1 Frequency 868MHz With the present declaration Sprue Safety Products Ltd confirms that the WTSL SN 1 conforms to the essential requirements an...

Page 3: ...nk 8 Making the Alarm Control Unit Tamper Proof 10 INSTALLATION GUIDE Testing the Alarm System 12 Product Functionality 13 Reorganising a Network 16 When an Alarm Sounds 17 LED Indicators 18 Troubleshooting 20 Maintenance 22 Disposal 23 Warranty 23 USER GUIDE ...

Page 4: ... to 10 minutes unless carbon monoxide has been detected in which case you can use the Locate function below to find the source alarm Locate button allowing you to silence all alarms but the initiating alarm during an alarm condition During a fault condition this feature will allow you to locate the alarm in fault in a similar way Alarm memory function allows you to investigate previous alarm event...

Page 5: ...5 Test Silence button Locate button Carbon monoxide alarm indicator Smoke Heat alarm indicator Fault indicator ...

Page 6: ...n who feels able to install it according to the instructions Read all installation instructions prior to installing this product WARNING To prevent injury this Alarm Control Unit must be securely attached to the wall in accordance with the installation instructions To mount the bracket onto a wall Please ensure that you use the screws provided as they were chosen specifically for use with this pro...

Page 7: ...e battery To activate the control unit remove the disabling tab Upon activating the control unit all three LED s should simultaneously flash twice to indicate that they are working Once the alarm is activated it can then be learnt into a Wi Safe 2 network before securing to the wall bracket ...

Page 8: ...eless alarms from other ranges or manufacturers The control unit needs to be learned in or interlinked in order to communicate within the network Wi Safe2 enables wireless communication with any other product with Wi Safe2 technology inside When one alarm detects smoke heat carbon monoxide the wireless module inside sends a signal to all the connected alarms ensuring almost instantaneous reaction ...

Page 9: ...efly press the test button on an alarm already in the network to wirelessly interlink the two The alarm will sound its audible test pattern 3 The red LED on the back of the control unit will flash to indicate that it has been learned in successfully If the test button is not pressed quickly enough the learn in process will fail If this happens repeat the process YourAlarm Control Unit counts as on...

Page 10: ...your alarm network prior to installing your Alarm Control Unit If you want to install your Alarm Control Unit first you can learn your smoke heat and CO alarm into it by following the instructions in your alarm manual using the Alarm Control Unit as alarm 1 MAKING THE ALARM CONTROL UNIT TAMPER PROOF Do not complete this action until you have wirelessly interlinked all of your alarms ...

Page 11: ... bracket using a small screwdriver being careful to support the bracket fully whilst doing so Once the rest of the installation is complete and the control unit is fixed to the bracket it can only be removed using the following method Insert a small screwdriver into the hole on the top right hand corner of the control unit until it stops this will disengage the lock then gently ease the control un...

Page 12: ...ll networked alarms should sound To stop the test earlier than 3 minutes simply press the Test Silence button again This test should be performed on a weekly basis Pressing the Test button on the Alarm Control Unit creates a lot of RF traffic If you need to use the feature more than once please wait for 5 minutes to let the network settle down USER GUIDE ...

Page 13: ...system sensitivity for up to 10 minutes Locate button In an alarm event this will silence all wirelessly interlinked alarms except the initiating alarm which has sensed carbon monoxide smoke Smoke heat alarm indicator This indicates that a smoke heat alarm has been activated Carbon monoxide indicator This indicates that a carbon monoxide alarm has been activated Fault indicator This indicates a fa...

Page 14: ...TTON If the alarms are sounding and the smoke heat alarm indicator is flashing but there s no obvious hazard pressing the Silence button will silence all wirelessly interlinked alarms and reduce the system sensitivity for up to 10 minutes However if excessive smoke is sensed the silence function will be overridden The indicator will continue to flash unless the smoke disappears Please Note An alar...

Page 15: ...f the alarm in fault sounds a unique SOS sound pattern continue to A below If no SOS sound pattern is heard proceed to B below A In case you need to locate the unit again please wait for 2 minutes before trying to locate for the SOS pattern Take down the alarm which is sounding Unlearn the alarm from the network using a ball point pen in the circular learn in hole in the back of the alarm Briefly ...

Page 16: ... the number of units in the network If successful once the reorganisation is complete the Control Unit should return to standby mode with no LEDs flashing If the reorganisation is not successful and LEDs are still flashing all 3 LED s flash together 3 times then a fourth flash only occurs repeatedly you will need to exit Reorganisation Mode To do this hold the Locate button for 5 seconds wait for ...

Page 17: ...the premises and call the fire brigade If the source of the alarm is not immediately apparent check which indicator is flashing on the control unit If the CO indicator is flashing Keep calm and open the doors and windows to ventilate the property Stop using all fuel burning appliances and ensure if possible that they are turned off Evacuate the property leaving the doors and windows open Ring your...

Page 18: ... Keep calm and open the doors and windows to ventilate the property Flashing rapidly every second Alarm Smoke heat has been detected Keep calm and evacuate the property Either the carbon monoxide indicator or the smoke heat indicator or both are flashing every 10 seconds This indicates that one of the alarms has previously been activated Please refer to the Locate section of this manual Either the...

Page 19: ...isation Mode hold the Locate button for 5 seconds wait a couple of minutes and then press and hold the Locate button for 5 seconds to start Reorganisation Mode again Flashing once every 5 seconds Low battery condition or the end of the product life The control unit should be replaced as soon as possible Flashing rapidly This indicates an internal fatal radio failure Please contactTechnical Support...

Page 20: ...09 When pressing the test button nothing is happening This indicates that the control unit has not been successfully activated see section Activating the Alarm Control Unit Unable to remove the control unit from its bracket You need to disengage the locking pins Refer to the Making the Alarm Control UnitTamper proof section If you have any questions about the operation of your Alarm Control Unit p...

Page 21: ...21 WTSL Compatibility Chart Function WST 630 Prior to 2014 Models WST 630 2014 Model onwards WHT 630 W2 CO 10X WSM SN 1 WHM SN 1 Test Silence Alarm Memory Locate Locate SOS Fault Finding Re organisation ...

Page 22: ...hment every 3 months Never use cleaning solutions on the control unit Simply wipe with a damp cloth Do not paint the control unit Do not spray aerosols on or near the control unit Do not use any solvent based products near the control unit Do not attempt to repair the control unit Do not attempt to change the battery Do not remove any screws or open the main casing of the control unit Any attempt ...

Page 23: ...rants that during the five year period commencing from the date of purchase Sprue Safety Products Ltd at its discretion agrees to replace the unit free of charge The warranty on any replacement WTSL SN 1 Alarm Control Unit will last for the remainder of the period of the original warranty in respect of the unit originally purchased that is from the date of original purchase and not from the date o...

Page 24: ... warranty of merchantability or fitness for a particular purpose is limited in duration for five years This warranty does not affect your statutory rights Except for death or personal injury Sprue Safety Products Ltd shall not be liable for any loss of use damage cost or expense relating to this product or for any indirect or consequential loss damages or costs incurred by you or any other user of...

Page 25: ...25 ...

Page 26: ...26 ...

Page 27: ...27 ...

Page 28: ...ncluded in all wireless products Carbon Monoxide Alarm Wireless W2 CO 10XT Heat Alarm Wireless WHM SN 1 Non Wireless HM SN 1 Smoke Alarm Wireless WSM SN 1 Non Wireless SM SN 1 Alarm Control Unit Wireless WTSL SN 1 ...

Reviews: