7
COOKER HOOD
HORIZONTAL INSTALL ATION UNDER COOKER HOOD
Allow the Heat Sensor to reach room temperature before use. The
power to the cooker must be switched off (fuse box). See the table
for the mounting location and follow the instructions from 1-4.
Starting the Sensor
Remove the red battery discon-
nection piece (B) and replace the
Sensor on the mounting plate.
Press in the Sensor cover (lamp
(A) flashes green).
Keep the battery disconnection
piece for future use.
Check installation height
Set the Sensor’s sensitivity level according to the mounting height.
The factory setting for sensitivity level is 45-60 cm above the cooker.
If the installation height is not between 45-60 cm sensitivity needs to be
set manually (see the table underneath and page 18, or watch the film
on sensitivity configuration).
3
DISTANCE FROM COOKER
TO SENSOR
MOUNTING LOCATION
SENSITIVITY LEVEL CONFIGURATION
0-60 cm wide
cooker
61-90 cm wide
cooker
Sensitivity
Acknowledgement "beep(s)"
81 - 100 cm
*
Zone 1 and 2
Zone 1
3 presses
77 - 80 cm
Zone 1 Zone 2
(
Note!
See EN
requirement, page
20, point 4)
Zone 1
(
Note
! See EN
requirem
e
nt, page
20, point 4)
4 presses
71 - 75 cm
5 presses
65 - 70 cm
6 presses
61 - 64 cm
7 presses
45 - 60 cm
Factory setting
8 presses
* For wall mounting lower than 80 cm and horizontal mounting 81-100 cm below the fan,
the sensor will not in all cases meet all EN standard requirements.
B
A
Watch the film on sensitivity
configuration (48 sec.)
goog.gl/eS3oZF
4