20
off on
off on
Remove the Sensor from the mounting plate. (Wait until the
Sensor emits four “beeps” ( ) and the cooker is
turned off.)
Put the battery disconnection piece into the space on the under-
side of the Heat Sensor (see image).
Hold the Heat Sensor in your hand and press the disconnection
piece and the cover towards each other and hold for about 5
seconds. Release your hold (the Sensor emits a “beep” ). Then
press the disconnection piece and the cover towards each other
again and hold for about 5 seconds. Release your hold (the
Sensor emits a “beep” ) and remove the battery disconnection
piece. If you have lost the disconnection piece, you can use a
screwdriver instead (see image).
Press the Heat Sensor cover once. The Sensor will now emit
“beeps”confirming its new setting: one “beep” ( ) signifies that
the Audible Alarm Detection is activated, two “beeps” ( )
signifies that the feature is deactivated.
Return the Heat Sensor to the mounting plate and press its
cover once.
Carbon monoxide / smoke alarm detection
1
3
2
4
The carbon monoxide / smoke alarm must be placed within 5
metres of the Control Unit. The Stove Guard is compatible with
virtually all alarms, but ensure correct alarm recognition by
testing the system first. If you wish to deactivate the feature
later, carry out the same procedure again.
2 U S E R G U I D E