TECHNICAL INFORMATION
Detector Specifications:
Model CO-9B
Sensor Type:
Electrochemical
Sensor Life:
7 Years
Alarm Sound Level:
85dB at 1m/3 feet
Recommended Batteries:
Size AA Alkaline - Duracell LR6, Energizer LR6, Gold Peak 15A
Battery Life:
Exceeds 1 year under normal operating conditions, replaceable
Temperature Range:
-10ºC (14ºF) to 40ºC (104ºF)
Operating Humidity Range: 30 - 90% RH
Weight (inc. batteries):
125 grams (4.4oz)
Certified to:
EN 50291-1: 2010, EN 50291-2: 2010
This FireAngel carbon monoxide detector is designed to continuously monitor for CO.
Its response times meet the requirements of the European standard EN 50291-1: 2010,
EN 50291-2: 2010.
The alarm will sound:
•
Between 60 and 90 minutes when exposed to 50ppm of CO
•
Between 10 and 40 minutes when exposed to 100ppm of CO
•
Within 3 minutes when exposed to CO levels of 300ppm or more