Recommended Batteries:
Duracell MN1604, Energizer 522, Gold Peak 1604A
Battery Life:
Exceeds 1 year, replaceable
Temperature Range:
-10ºC (14ºF) to 40ºC (104ºF)
Operating Humidity Range:
30-90% RH
Weight:
228 grams (10 oz), including battery
Certified to:
BS EN 50291:2001
The FireAngel carbon monoxide detector is designed to monitor for CO and to display levels between
10 and 999ppm where a reading of more than 10ppm is detected at the sensor.
If the level of CO
detected at the sensor is less than 10ppm, then the display will read 0ppm.
The following
response times meet the requirements of the British Standard BS EN 50291:2001.
The high-level alarm will sound:
• Between 60 and 90 minutes when exposed to 50ppm of CO.
• Between 10 and 40 minutes when exposed to 100ppm of CO.
• Within 3 minutes of exposed to 300ppm of CO.
The low level CO warning will activate when concentrations of CO of more than 30ppm but not more
than 50ppm have been detected for at least 2 hours.
WARNING:
APPARATUS CONFORMING TO THIS STANDARD MAY NOT PROTECT PEOPLE WHO
ARE AT SPECIAL RISK FROM CARBON MONOXIDE EXPOSURE BY REASON OF AGE, PREGNANCY
OR MEDICAL CONDITION. IF IN DOUBT, CONSULT YOUR MEDICAL PRACTITIONER.
A CARBON MONOXIDE DETECTOR IS NOT A SUBSTITUTE FOR A SMOKE ALARM OR A
COMBUSTIBLE GAS DETECTOR. REPLACE UNIT AFTER 5 YEARS OF OPERATION.
25