Optional Accessories
14
Document #50801 Rev.B 8/17/98 P/N 50801:B
AFM Series Annunciators (LED Zone Type)
The AFM Series Annunciators remotely display system status. The AFM/AEM-16AT annunciators display zone
alarm and trouble status. In addition, they provide remote Acknowledge, Silence, Reset and Drill functions. The
AFM Series Annunciators require the use of the LED-10IM Interface Module. For more detailed information,
refer to the appropriate AFM Annunciator manual.
✓
AFM-16ATX - The Annunciator Fixed Module-16ATX contains
16 red alarm and 16 yellow trouble LEDs, a system trouble LED,
an ON LINE/POWER LED and a local piezo sounder with
switches for Acknowledge, Silence, Reset and Drill. The
AFM-16ATX is fixed at address '1' and will accept up to 3
AEM-16ATF Expanders. The AFM-16ATX can be mounted in a
Fire•Lite ABS-1F or ABF-1F backbox. Refer to the AFM-16ATX
Manual for detailed information. Note that only one A FM-16ATX
is required to annunciate 10 zones of alarm and trouble, provided '8
Point Shift' function is selected. Refer to A nnunciator Manual P/N
15390 for additional information.
✓
AFM-16ATXCS4 (Canadian Supervisory Service) - This mod-
ule is the same as the AFM-16ATX except with four yellow super-
visory LEDs in place of the four red LEDs at points 13 through 16.
✓
AFM-16ATXCS8 (Canadian Supervisory Service) - This module is the same as the AFM-16ATX
except with eight yellow supervisory LEDs in place of the eight red LEDs at points 9 through 16.
✓
AFM-16ATXCS16 (Canadian Supervisory Service) - This module is the same as the AFM-16ATX
except with sixteen yellow supervisory LEDs in place of the sixteen red LEDs at points 1 through 16.
✓
AEM-16ATF - The Annunciator Expander Module-16ATF connects to the AFM-16ATX and adds 16
sets of red alarm LEDs and yellow trouble LEDs. Up to three AEM-16ATFs may be added to an
AFM-16ATX but only one is required. Note that one A EM-16ATF is required with an A FM-16ATX to
annunciate 10 zones of alarm and trouble as well as general system status provided '8 Point Shift' func-
tion is not selected. Refer to A nnunciator Manual P/N 15390 for additional information.
✓
AFM-16ATF - The Annunciator Fixed Module-16ATF contains
16 red alarm and 16 yellow trouble LEDs, a system trouble LED,
an ON LINE/POWER LED and a local piezo sounder with
switches for Acknowledge, Silence, Reset and Drill. The
AFM-16ATF is fixed at address '1' and communication is via the
EIA-485 data line. The AFM-16ATF can be mounted in a
Fire•Lite ABS-1F or ABF-1F backbox. Refer to the AFM-16AT
Manual for detailed information.
✓
AFM-16AF - The Annunciator Fixed Mod-
ule-16AF has 16 red alarm LEDs. Multiple
annunciators may be used by setting all annunci-
ators to Receive Only, except the last AFM-16AF
in line. Each annunciator's address is internally
fixed at '1' and communication is via the EIA-485
data line. The Local Silence/Acknowledge
switch functions as local lamp test and silence for
annunciator piezo. LEDs include On-Line and
System Trouble indicators. The AFM-16AF
Annunciator can be mounted in a standard 4-
gang electrical box. Refer to the AFM-16AF
Manual for detailed information.
FIGURE 1-10:
AFM-16ATX
FIGURE 1-11:
AFM-16ATF
FIGURE 1-12:
AFM-16AF
Summary of Contents for MS-2410BC
Page 6: ...6 Document 50801 Rev B 8 17 98 P N 50801 B MS 2410BC Terminals and Connectors AC Power ...
Page 56: ...Slide in Labels 56 Document 50801 Rev B 8 17 98 P N 50801 B ...
Page 58: ...Slide in Labels 58 Document 50801 Rev B 8 17 98 P N 50801 B ...
Page 60: ...Slide in Labels 60 Document 50801 Rev B 8 17 98 P N 50801 B ...
Page 61: ...Document 50801 Rev B 8 17 98 P N 50801 B 61 Notes ...
Page 62: ...62 Document 50801 Rev B 8 17 98 P N 50801 B Notes ...
Page 63: ...Document 50801 Rev B 8 17 98 P N 50801 B 63 Notes ...