Fire-Lite Alarms SD355CO Installation And Maintenance Instructions Download Page 4

FL-400-006  4 I56-4129-000 
 

 

©2014 Fire-Lite

FCC STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used 
in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installa-
tion. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures:
 

 

– Reorient or relocate the receiving antenna.

 

 

– Increase the separation between the equipment and receiver.

 

 

– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

 

 

– Consult the dealer or an experienced radio/TV technician for help.

Please refer to insert for the Limitations of Fire Alarm Systems

Summary of Contents for SD355CO

Page 1: ...move power from the communication line before installing sensors 1 Wire the sensor base supplied separately per the wiring diagram see Figure 1 2 Set the desired address on the sensor address switches see Figure 2 3 Install the sensor into the sensor base Push the sensor into the base while turning it clockwise to secure it in place SPECIFICATIONS Operating Voltage Range 15 to 32 VDC Standby Curre...

Page 2: ... in Figure 3 for 6 12 seconds NOTE If the magnet is held in place for too long the fire alarm test function will be triggered Reset the panel and proceed with testing the CO portion of the device It may be preferred to put the device into fire alarm first via the magnet test to ensure the device has successfully entered test mode 2 Spray a UL approved CO agent into the top ring of the detector s g...

Page 3: ...essed air to remove dust and debris from the sensing chamber and sensing chamber cover 6 Re install the sensing chamber cover assembly by sliding the cover over the chamber gently pressing it home until it snaps into place 7 Re install the sensor cover Use the cover removal tabs LEDs and therm istors to align the cover with the sensor Snap the cover into place 8 When all sensors have been cleaned ...

Page 4: ...iate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enc...

Reviews: