LISTING INFO
OMNI-TEST LABORATORIES INC.
!
4
The Firebowls have been product certified by OMNI-
Test Laboratories, Inc. (OMNI) is a full service hearth
product testing laboratory with state-of-the-art emis-
sions and safety measurement and analysis equip-
ment. OMNI’s product testing programs are accredited
by national and international accreditation bodies
including, the American National Standards Institute
(ANSI), the Standards Council of Canada (SCC), the In-
ternational Accreditation Service, Inc. (IAS), and the
U.S. Environmental Protection Agency (EPA). OMNI is
also recognized by various other state, provincial, and
city jurisdictions.
Mailing Address: P.O. Box 301367 Portland, OR 97294
Phone: 503.643.3788 Fax: 503.643.3799
Email: [email protected]
Model: Firebowl
ANSI Z21.97-2012/CSA 2.41-2012
OUTDOOR DECORATIVE GAS APPLIANCES
Type of Gas: Natural Gas (NG), Liquid Propane (LP)
Report # 388-0-01b-5
ORIFICE SIZES:
45” Models:
LP Maximum BTU = 150,000 w. #26 DMS orifice @ 11” W.C. Inlet - 10” W.C. Manifold
NG Maximum BTU = 150,000 w. #6 DMS orifice @ 7” W.C. Inlet - 6” W.C. Manifold
54” & 68” Models:
LP Maximum BTU = 300,000 w. #4 DMS orifice @ 11” W.C. Inlet - 10” W.C. Manifold
NG Maximum BTU = 300,000 w. #K DMS orifice @ 7” W.C. Inlet - 6” W.C. Manifold
INSTALLATION & SERVICE BY CERTIFIED GAS TECHNICIAN ONLY
CAN/CGA 2.17-M91 (R2009) Gas-Fired Appliances for Use at High Altitudes
THIS APPLIANCE IS EQUIPPED FOR ALTITUDES OF:
U.S. 0-2000FT. (0-610 M) – CANADA 0-4500FT. (0-1,372 M)
LP MAXIMUM SUPPLY PRESSURE: 2PSI
Minimum gas pressure for propane - 10" W.C.
Minimum gas pressure for natural gas - 5" W.C.
MINIMUM CLEARANCE TO COMBUSTIBLES:
Top: 12ft (144”) - Sides: 2ft (24”)
INSTALLATION ON (OR OVER) NON-COMBUSTIBLE FLOORS ONLY.
TO LIGHT APPLIANCE:
•
OPERATE AT ARMS LENGTH
•
DO NOT LEAN OVER APPLIANCE
•
USE SAFETY GOGGLES & EXTENDED TORCH
•
1. MAKE SURE GAS VALVE CONTROL KNOB ON APPLIANCE IS IN THE
OFF
POSITION
2. TURN ‘PLAIN VIEW’ EMERGENCY SHUT-OFF VALVE TO
ON
OR
OPEN
POSITION
3. LOCATE PILOT LIGHT ON BURNER & PILOT SIGHTING TUBE INSIDE APPLIANCE
4. TURN GAS VALVE CONTROL KNOB ON APPLIANCE TO
LOW
POSITION
5. PUSH RED BUTTON FOR PILOT & HOLD
6. IMMEDIATELY PUT TORCH INSIDE PILOT SIGHTING TUBE & IGNITE PILOT. CONTINUE TO
HOLD RED PILOT BUTTON DOWN FOR 30 SECONDS UNTIL PILOT STAYS LIT
7. RELEASE BUTTON & REMOVE TORCH FROM SIGHTING TUBE. MAKE SURE PILOT STAYS LIT
8. TURN GAS VALVE CONTROL KNOB ON APPLIANCE SLOWLY TO
HIGH
POSITION
9. ADJUST FLAME HEIGHT TO PREFERENCE
IF BURNER DOES NOT LIGHT OR YOU SMELL OR HEAR GAS, IMMEDIATELY TURN GAS VALVE CONTROL
KNOB ON APPLIANCE TO OFF POSITION.
TO PUT OUT APPLIANCE:
1. TURN ‘PLAIN VIEW’ SHUT-OFF VALVE TO
OFF
OR
CLOSED
POSITION.
2. WAIT FOR GAS TO BURN OUT OF LINE.
3. TURN GAS VALVE CONTROL KNOB ON APPLIANCE TO
OFF
POSITION.
ALWAYS SHUT DOWN IN THIS MANNER: GAS LINE FIRST, APPLIANCE SECOND.
TO RE-LIGHT BURNER, WAIT 5 MINUTES AFTER A COMPLETE SHUT-OFF.
English
CAUTION:
THE GAS PRESSURE REGULATOR PROVIDED WITH THIS APPLIANCE MUST
BE USED. THIS REGULATOR IS SET FOR AN OUTLET PRESSURE OF 11” WATER COLUMN
FOR LP & 6” WATER COLUMN FOR NG.
WHAT TO DO IF YOU SMELL GAS OR SUSPECT A LEAK:
• Do not t
ry to light any appliance.
• Do not touch a
ny electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone.
•
Follow the gas supplier’s instructions.
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to the owner’s
information manual provided with this appliance. For assistance, or additional
information, consult a qualified installer, service agency, or the gas supplier.
!
WARNING:
Do not store or use gasoline, or other flammable vapors
and liquids, in the vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of
this or any other appliance.
!
DANGER!
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in a enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper,
tent, or home