MANUAL PILOT FIREBOWL
Side Mounted Ignition
•
45
•
54
•
68 NL & LL Firebowl
MAINTENANCE
VISUAL MAINTENANCE
In order to keep your fire feature function-
ing properly and efficiently, a visual check
of its components is necessary. The vital
components to prove are the pilot burner
and main burner while they are lit.
Before looking at these components, re-
move all lava stones and any debris from
the bowl.
Also remove the pilot guard and put aside.
Once you have removed all debris, light the
appliance according to the “ignition” sec
-
tion in this manual. (see pg. 24-25 )
While the main burner is on, turn the flame
height valve to the OFF or CLOSED position.
This will leave the pilot burner on and the
main burner off.
Visually check that the pilot has a robust
flame and is making contact with the ther-
mocouple above it. (See illustration at left
for a normal flame pattern.)
After visually inspecting the pilot flame and
establishing it is in normal working condi-
tion, the next thing to check is the main
burner.
To turn the main burner on for a visual
check, while the appliance is in operation,
turn the flame hight valve to the LOW po-
sition. Carefully check that the burner has
a even, steady flame coming out of all the
drilled ports along the burner.
Now that the appliance has been visually
checked, turn the appliance OFF, follow-
ing the “to put burner out” section in this
manual. (see pg.25)
If either the pilot burner or the main burner
appears to burn unevenly or abnormally,
please contact the manufacturer or a quali-
fied service person for repair. If the burner
is found faulty or evidence of corrosion and
needs repair, the replacement burner must
come from the original manufacturer. Do
not operate the fire feature until the re-
placement burner has been installed by a
qualified service person.
Remove Pilot Guard
Pilot Burner Flame
Main Burner Flame
30