VISUAL MAINTENANCE

In order to keep your fire feature function-
ing properly and efficiently, a visual check 

of  its  components  is  necessary.  The  vital 

components to prove are the pilot burner 

and main burner while they are lit.

Before looking at these components, re-
move all lava stones and any debris from 

the bowl.

Also remove the pilot guard and put aside.

Once you have removed all debris, light the 

appliance  according  to  the  “ignition”  sec

-

tion in this manual. (see pg. 24-25 )

While the main burner is on, turn the flame 

height valve to the OFF or CLOSED position. 

This will leave the pilot burner on and the 

main burner off.

Visually check that the pilot has a robust 
flame and is making contact with the ther-

mocouple above it. (See illustration at left 
for a normal flame pattern.)

After visually inspecting the pilot flame and 
establishing it is in normal working condi-

tion, the next thing to check is the main 

burner.

To turn the main burner on for a visual 

check, while the appliance is in operation, 
turn the flame hight valve to the LOW po-

sition.  Carefully  check  that  the  burner  has 

a even, steady flame coming out of all the 

drilled ports along the burner. 

Now that the appliance has been visually 

checked, turn the appliance OFF, follow-

ing the “to put burner out” section in this 
manual. (see pg.25)

If either the pilot burner or the main burner 

appears to burn unevenly or abnormally, 

please contact the manufacturer or a quali-

fied service person for repair. If the burner 

is found faulty or evidence of corrosion and 
needs repair, the replacement burner must 

come  from  the  original  manufacturer.  Do 

not operate the fire feature until the re-
placement burner has been installed by a 

qualified service person.

Remove Pilot Guard

Pilot Burner Flame

Main Burner Flame

30

Summary of Contents for FIREBOWL 45 L

Page 1: ...able vapors or liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance CARBON MONOXIDE HAZARD Thi...

Page 2: ......

Page 3: ...1 22 24 25 26 28 29 31 Listing Information Purchase Agreement Warnings Warranty Information Overview Size Chart Components Control Panel Venturi Orifice Burner Pilot Pilot Guard Pilot Sighting Tube Mo...

Page 4: ...NER PILOT SIGHTING TUBE INSIDE APPLIANCE 4 TURN GAS VALVE CONTROL KNOB ON APPLIANCE TO LOW POSITION 5 PUSH RED BUTTON FOR PILOT HOLD 6 IMMEDIATELY PUT TORCH INSIDE PILOT SIGHTING TUBE IGNITE PILOT CON...

Page 5: ...ss from and against any claim loss damage or expense including reasonable attorneys fees resulting or arising from a breach of Buyer s warranty 2 Prices The prices specified are not subject to change...

Page 6: ...y The Company and will not be processed if received after the expiration date The RMA number must be indi cated on the outside of the return package and a copy of the RMA in the package with product I...

Page 7: ...insurance as the Company or Buyer may determine is reasonably necessary to insure against injury to persons and property by reason of such on site installations The policy shall be in the name of the...

Page 8: ...located in New York County the State of New York Buyer consents to the jurisdiction of such courts and waives any defense based on lack of jurisdiction or forum inconveniens 12 Ownership of Designs Bu...

Page 9: ...minimum operating pressure 5 inches water column maximum operating pressure 7 inches water column MANUAL PILOT IGNITION SYSTEM SPECIFICATIONS Includes Mounted instructional control panel with 3 4 gas...

Page 10: ...emicals plastics petroleum products electronics motors vehicles fer tilizer gun powder ammunition firearms fireworks fabrics paper products wood dry vegetation etc Do not operate appliance during an e...

Page 11: ...sed quarters the propane or natural gas required to operate the appliance as well as to post or secure the appliance from unknowing persons contacting the appliance while it is in operation or hot eit...

Page 12: ...ssageways of the appliance be kept clean to provide for ad equate combustion and ventilation air This appliance is only for use with the type of gas indicated on the rating plate This appliance is not...

Page 13: ...e in or near flame Do not throw foreign objects or any liquids into appliance Do not operate this appliance under the influence of alco hol or drugs The firebowl does not come supplied with rocks 100...

Page 14: ...ons to permit the entrance of a 1 8 inch 3 2 mm diameter rod Gas supply valves must be readily accessible for hand opera tion A door on the enclosure to gain access to the gas sup ply valves is accept...

Page 15: ...The burner for this appliance is assembled and tested by Charles A Hones Inc P O Box 405 355 NY State Route 49 Cleveland NY 13042 315 623 2124 The burner is a special stainless steel Yel low Flame bu...

Page 16: ...MANUAL PILOT FIREBOWL Side Mounted Ignition 45 54 68 NL LL Firebowl 45 DIAMETER LL LITTLE LIP NL NO LIP 54 DIAMETER LL LITTLE LIP NL NO LIP 68 DIAMETER L LIP NL NO LIP SIZE CHART LIP OPTIONS 16...

Page 17: ...Guard Pilot Assembly Venturi Air Mixer Venturi Air Shutter Orifice 1 2 Connection to Control Valve Gas Valve Control Knob Baso Safety Valve Maxitrol 325 5AL Low Pressure Regulator Control Panel COMPON...

Page 18: ...LEGEND Burner Plate Pilot Lighting Button Control Panel Gas Valve Control Knob BEHIND THE FRONT PLATE LEGEND H15DA 3C Baso Safety Valve 3 4 Ball Valve Flame adjustment K16BA 48 22 Baso Thermocouple 1...

Page 19: ...ession Tube Fitting Elbow Adapter OXYGEN INTAKE ADJUSTMENT The Venturi is factory set with a set screw Before operation check to see that the Ven turi is set in the position to the left The positionin...

Page 20: ...ner tested prior to shipping LEGEND Burner Mounting Leg 1 Schedule 40 Stainless Steel Cross Burner 90M Stainless Steel Venturi Air Mixer LEGEND Pilot Sighting Tube Mounting Post 1 4 Gas Feed Pilot Mou...

Page 21: ...ch keeps the lava rocks from damaging the pilot assembly PILOT SIGHTING TUBE The Pilot Sighting Tube allows you to guide the torch to the proper location to light the pilot when the firebowl is filled...

Page 22: ...1 2 hole 5 1 2 deep in a stable mount ing platform recommended a 20 diameter sonotube concrete footing Hammer Expansion Anchor Bolt into the hole The bolt should stick out 2 1 2 Remove washer and scre...

Page 23: ...d is installed The heat shield comes welded to the ball feet the firebowl sits on See clearances on the next page MOUNTING 23 SECTION A SECTION A A FIREBOWL EQUIPPED WITH A LOWER HEAT SHIELD IS MOUNTE...

Page 24: ...tible materials when a heat shield is installed See page 23 for mounting a firebowl with a heat shield Test recorded temperatures with heat shield Floor temperature 150 F CLEARANCES 24 A B A B 144 COM...

Page 25: ...ated at a minimum of 150 000 and a maximum of 300 000 BTU s The burner is supplied with the appropriate 1 4 brass orifice for use with either natural gas NG or propane LP a modified 90M stainless stee...

Page 26: ...ntrol knob on appliance to LOW position Push red button for pilot and hold Immediately put torch inside pilot sighting tube and ignite pilot Continue to hold down button for 30 seconds or until pilot...

Page 27: ...UT BURNER OUT TURN PLAIN VIEW SHUT OFF VALVE TO OFF OR CLOSED POSITION WAIT FOR GAS TO BURN OUT OF LINE TURN GAS VALVE CONTROL KNOB ON APPLI ANCE TO OFF POSITION ALWAYS SHUT DOWN IN THIS MANNER GAS LI...

Page 28: ...ailable Lava rocks come in all sizes from pebbles to boulders 2 6 lava rock is the best size to use with your firebowl You will need ap proximately 100 to 200lbs for the firebowls If you are unable to...

Page 29: ...on is correct and that pilot reliably and accurately ignites main burner Use a tooth pick or thin wire to poke out any clog or obstruction from the small holes in the burner ONLY WHEN BURNER IS OFF Ch...

Page 30: ...at left for a normal flame pattern After visually inspecting the pilot flame and establishing it is in normal working condi tion the next thing to check is the main burner To turn the main burner on...

Page 31: ...2 8 Baso Brass Pilot Orifce Assembly Includes NG or LP Orifice 9 1 4 O D Pilot Light Feed Tubing 10 Baso Thermocouple K16BA 48 22 PILOT GUARD SIGHTING ASSEMBLY 11 Pilot Guard 12 Pilot Sighting Tube MA...

Page 32: ......

Reviews: