![FIORENTINI S32B User Manual Download Page 32](http://html.mh-extra.com/html/fiorentini/s32b/s32b_user-manual_2290501032.webp)
MAINTENANCE
S32B
Revision 00 Maggio 2006
Page 32 di 37
5.2
BATTERY MAINTENANCE
Control of battery charge can be easily made when the operator is working with the machine through the
indicator placed on the control bridge. It shows the following information :
¾
On green : the battery is charged
¾
On yellow : the battery is half-charged
¾
On red : the battery is flat
During charging don’t let the battery box opened
¾
Don’t use fire and no smoke nearby the batteries
¾
Take care to the liquid because corrosive
¾
Don’t sparkle close to the batteries
¾
Battery gas is explosive
¾
Never invert the polarity
5.2.1
DENSITY MEASUREMENT
Hydrometry can be made with batteries under charge with a densimeter. Do as it follows :
¾
Put the gun densimeter and take a quantity of electrolyte sufficient to push up the floating;
¾
Keep care the top of it doesn’t touch the rubber or the glass walls.
¾
For a measure of density, after filling up with distilled water, density has to be uniform in the box.
5.2.2
WATER FILLING UP
¾
Put distilled water in each cell of the battery before charging the batteries to take the liquid at 6
mm over the plates.
¾
This operation has to be made every time the level goes down, but never over a week between
two filling up.
5.2.3
CHARGING LIMITS
It’s not necessary to charge the battery if density, after a working day, is underneath 1,24 (28 Bè). The best
recommended temperature is 45°C. If the electrolyte temperature goes up of 10/12°C inside facing to room
temperature, it can be overcharged without depending from the normal use.
5.2.4
OFF DUTY OR INACTIVE BATTERIES
While inactive, the batteries can go flat by themselves. If battery is not frequently used, it may occurs to do
the following operations:
¾
Once in a month place it under charge, to a voltage indicated as “final”, until all elements are full
of gas and is possible to read tension and specific weight for 3-4 hours about ;
¾
It’s necessary to do it even when measurements of specific weight show high values. If battery
stays inactive longer it has to be preserved in a dry place.