INDUSTRIAL CLEANING MACHINES
fig. 6
REVISIONE N°05/001
Notice:
during operation with the suction hose, the manual pipe can get closed. The light will go on but there is no any
failure.
PAPER BAG REPLACEMENT
To replace paper bag open the upper cover of the carpet sweeper. Pull out the paper bag.
BRUSH STRIP REPLACEMENT
Unscrew the 3 screws placed under the brush head “6.2” remove out the brush, remove the RH support “6.3” and remove
the brush strip “6.1” and replace it with new one.
TROUBLESHOOTING
Blocked brush:
The brush motor is stopped by the electronic unit built-in in the carpet sweeper. The red light shows this state.
Remedy:
Disconnect the carpet sweeper from mains, check if the brush is dirty and remove any possible blocking object.
Restart the carpet sweeper.
Clogged hose:
Stop the carpet sweeper, remove the hose from the brush head. Draw the hose in horizontal position and start the carpet
sweeper. If the obstruction still persists, remove it by means of a stab or similar mean.
TECHNICAL DATA
Suction data:
Vacuum motor: 5 A
Water lift:
71 inches
Air flow:
92 cfm (cubic feet a minute)
Voltage:
220 Volt, 50 Hz
Brushes:
Brush motor: 200 Watt
Traction:
timing belts
Brush stripe:
replaceable
Dimensions and Weight:
Height:
50 inches
Width:
18 inches
Weight:
17 lb
ING. O. FIORENTINI S.p.A.
6