MAINTENANCE
Ecosmall
Rev. 000
29/11/2017
37/41
5.4 WIRING SYSTEM CHECKS
The machine wiring system should be inspected and examined every 2 years. It is very important to
immediately correct any defects, e.g. disconnected wires or burnt cables.
Any service on the wiring system should be carried out by a skilled technician.
Any maintenance or repair not described as routine maintenance should be carried out by
specialised personnel authorised by FIORENTINI.
5.5 INSPECTION SUMMARY TABLE
FREQUENCY
REQUIRED TECHNICIAN
INSPECTIONS
Safety devices
2 years
Skilled technician
Electrical wiring
system
2 years
FIORENTINI technician
Braking system
3 months
Skilled technician
Complete
overhauling
5 years
FIORENTINI technician
MAINTENANCE
Recovery tank
cleaning
Daily
operator
Suction motor filter
Daily
operator
Clean water tank
filter
Monthly
operator
Suction pipe lines
cleaning
Weekly
operator
Squeegee cleaning
Weekly
operator
State of blades
inspection
Weekly
operator
Battery fluid level
inspection
Weekly
operator
Battery cable fixing
6 months
Skilled technician
Motor brush level in
each motor
inspection
Yearly
Skilled technician