23
Cover frame
To minimize the radiation of the sauna stones to the cabin wall, the enclosed cover frame (Fig.1,
Pos.1) must be installed. Unscrew the middle screw out of the inner panel (Fig.8). Apply the cover
panel with high chamfer to the Saunaheater rear onto the 4 outer screw heads. The 4 screw heads
mate in according cuts of the cover frame. Screw the cover panel with the middle screw to the inner
panel.
Middle screw
Fig.8
Tip when starting up the Saunaheater
We know that the heating rods are hygroscopic. This means that they absorb moisture, which could
result in the FI safety switch being triggered even in the absence of an actual fault.
In that event, the furnace must be heated up under supervision by a professional, disabling the protec-
tive function of the FI safety switch. Once the moisture has escaped from the heating elements after
around 10 minutes, the FI safety switch can be re-activated.
The likelihood of the heating elements having absorbed moisture and triggering the FI safety switch
increases the longer the furnace is left unused. For this reason, we recommend regularly heating up
the furnace for several minutes.