1. Fields of application

For optimum control over all laboratory work. The
adjustable magnification enables maximum micro-
metre (μm) precision. Fine-tuning of the objective
height using the round adjustment screws provided
on both sides.

2. Device setup

1

Ocular

2

Dioptre compensation

3

Clamping screw for microscope head

4

Objective tube

5

Drive knob for height adjustment

6

Drive box with stand compartment

7

Locking knob (for locking when using 
the table stand)

8

Ocular viewfinders

9

Objectives

10

Episcopic illumination (ring light)

11

Plastic screws for episcopic illumination 
(ring lights)

12

Socket for connecting the mains adapter cable

13

On/off switch for episcopic illumination 
(ring light)

14

MAX-MIN control

15

Specimen stage

16

Clamping screw for specimen stage

17

Table stand

3. Safety precautions

Warning! Failure to observe this safety

information can result in electric shock! Keep
the device out of the reach of children.

• Only connect the episcopic illumination 

(ring light) of the device to a properly 
connected mains socket with a mains voltage of
230 V/50 Hz using the mains adapter supplied.

• Check the mains adapter, power cable and 

device for damage prior to operation.

• If damage is identified, take the device 

out of service and ensure that it cannot be put
back into operation. Have the device repaired 
by an authorised specialist or by FINO GmbH.

• Do not open or repair the adapter housing, 

otherwise safety is not ensured and the warranty
with become void.

• Protect the device against damp and 

moisture.

• The mains adapter includes protection against

overheating and switches itself off automatically
after four hours of continuous operation. The
device must be allowed to stand for approx. one
hour before it may be switched on again.

3

ENU

It is essential to read the instructi-
ons for use carefully prior to ope-
ration and to keep these readily
available.

This symbol indicates safety pre-
cautions where non-compliance
can lead to risks for persons.

This symbol indicates safety pre-
cautions where non-compliance
can lead to damage of the device
and its function.

Summary of Contents for 86000

Page 1: ...a n i a FINO der feine Unterschied the fine difference la fine différence la fina diferencia la fine differenza 86000 86001 mit Stativ mit Gelenkarm with table stand with articulated arm avec trépied de table avec un bras articulé con el pie de sobremesa con el brazo articulado con stativo con braccio snodato met statief met scharnierarm se stativem s kloubovým ramenem med stativ med ledad arm áll...

Page 2: ... setup 3 3 Safety precautions 4 4 Getting started 4 Prior to commissioning location 5 Handling 4 Using with a stand item no 86000 Using with a joint arm item no 86001 Working with an LED ring light 6 Service and maintenance 7 7 Storage 7 8 Technical data 7 9 Delivery forms 7 10 Guarantee 7 11 Disposal 8 CONTENTS 2 ...

Page 3: ... connect the episcopic illumination ring light of the device to a properly connected mains socket with a mains voltage of 230 V 50 Hz using the mains adapter supplied Check the mains adapter power cable and device for damage prior to operation If damage is identified take the device out of service and ensure that it cannot be put back into operation Have the device repaired by an authorised specia...

Page 4: ...atures direct sunlight strong vibra tions blows or impacts 5 Handling 5 1 Using with a stand item no 86000 The device is supplied almost entirely pre assem bled Raise the microscope knob a few centimetres using the drive knob 5 Loosen the clamping screw for the microscope head 3 and turn the microscope knob so that the oculars 1 are facing the user Secure the clamping screw 3 again Place both ocul...

Page 5: ...the swivel move ment of the joint arm Flexible assembly of the joint arm using the table clamp The work surface is not damaged Unscrew the four pre assembled machine screws from the table clamp supplied For easier assembly remove the screw on flange from the lower end of the joint arm To do so unscrew and remove both socket head screws from the side of the flange using the socket wrench supplied a...

Page 6: ...s 1 and adjust the ocu lar distance in line with the interpupillary distance by turning the objectives 9 inwards or outwards Place the specimen to be viewed under the microscope on the specimen stage In the case of larger specimens the distance setting selected using the drive knobs at the side may not be sufficient Adjusting the distance using the joint arm see section on joint adjustment Guide v...

Page 7: ... Store unit in a dry and dust free place 8 Technical data 8 1 With stand item no 86000 Metal stand column length 18 0 cm Flat base 20 0 x 15 0 cm Widefield oculars pair WF 10x Revolver 1x and 2x for magnification 10x 20x LED episcopic illu mination ring light 100 240 V 50 60 Hz 3 6 W Power cable 2 m 8 2 With joint arm item no 86001 Metal joint arm 85 0 cm Widefield oculars pair 10x Magnification 1...

Page 8: ...t time and then use it FINO GmbH cannot be held liable for damages due to improper use or due to modifications made to the device itself The warranty will be voided if the unit is used for any purpose other than its proper intended purpose FINO GmbH has a policy of conti nuously developing and improving its products FINO GmbH reserves the right to make changes or impro vements to the products desc...

Page 9: ...9 ENU ...

Page 10: ...FINO GmbH Mangelsfeld 18 D 97708 Bad Bocklet Tel 49 97 08 90 94 20 Fax 49 97 08 90 94 21 info fino com www fino com ...

Reviews: