FTLF1217P2xTL Pluggable SFP Product Specification – September 2008
II.
Absolute Maximum Ratings
Parameter Symbol
Min
Typ
Max
Unit
Ref.
Maximum Supply Voltage
Vcc
-0.5
4.0
V
Storage Temperature
T
S
-40 85
°
C
Case Operating Temperature
T
A
-40 85
°
C
Relative Humidity
RH
0
85
%
1
III.
Electrical Characteristics
(T
A
= -40 to 85
°
C, V
CC
= 3.0 to 3.6 Volts)
Parameter Symbol
Min
Typ
Max
Unit
Ref.
Supply Voltage
Vcc
3.0
3.6
V
Supply Current
Icc
300
mA
Transmitter
Input differential impedance
R
in
100
Ω
2
Single ended data input swing
Vin,pp
250 1200
mV
3
Transmit Disable Voltage
V
D
2 Vcc
V
4
Transmit Enable Voltage
V
EN
Vee
Vee+ 0.8
V
Receiver
Single ended data output swing
Vout,pp
250 450 900 mV
5
Data output rise/fall time
≤
155 Mb/s
t
r
/t
f
0.6 5.0 ns
6
LOS Fault
V
LOS fault
2
Vcc
HOST
V 7
LOS Normal
V
LOS norm
Vee
Vee+0.5
V
7
Power Supply Rejection
PSR
100
mVpp
8
Systematic Jitter Contribution
RX
Δ
SJ
2.0
ns
9
Contributed Duty Cycle Distortion
RX
Δ
DCD
1.0
ns
10
Data Dependent Jitter Contribution
RX
Δ
DDJ
1.2
ns
10
Random Jitter Contribution @ OC-3
and OC-1
RX
Δ
RJ
0.6
ns
9
Random Jitter Contribution @ FE
RX
Δ
RJ
0.76
ns
10
Notes:
1.
Non condensing.
2.
Connected directly to TX data input pins. AC coupling from pins into driver IC.
3.
We recommend <600mV for best EMI performance.
4.
Or open circuit.
5.
Into 100 ohms differential termination.
6.
10 – 90 %
7.
LOS is an open collector output. Should be pulled up with 4.7k – 10kohms on the host board. Normal
operation is logic 0; loss of signal is logic 1. Maximum pull-up voltage is 5.5V.
8.
Receiver sensitivity is compliant with power supply sinusoidal modulation of 20 Hz to 1.5 MHz up to
specified value applied through the recommended power supply filtering network.
9.
Peak-to-peak measurement for OC-3 SR-0 or OC-1 SR-0 operation measured with a PRBS 2
23
-1 test
pattern.
10.
Peak-to-peak measurement based on 4B/5B encoded Fast Ethernet pattern referenced in FDDI PMD
3
Annex A.5
©
Finisar Corporation September 13, 2008 Rev. B
Page 4