H3i

Stand-alone Fingerprint & 
Card Access Control System 

SPECIFICATIONS

MODEL
SURFACE FINISHING
TYPE OF SCANNER
PROCESSOR
MEMORY
ALGORITHM
PRODUCT DIMENSION (L X W X H), mm
STORAGE

• Fingerprint template 
• Card
• Password
• Transaction 

ENROLLMENT & VERIFICATION 

• Methods
• Recommended fingerprint per user ID
• Fingerprint placement
• Password length
• Verification time (sec)
• FAR (%)
• FRR (%)

CARD TECHNOLOGY

• RFID: 64-bit, 125kHz
• MIFARE: MFIS50/S70, 13.56MHz

OPERATING ENVIRONMENT

• Temperature (°C)
• Humidity (%)
• Power input 

ACCESS CONTROL

• EM lock driving output
• Alarm output
• Door sensor

GROUP VERIFY TYPE

H3i
Acrylonitrile Butadiene Styrene (ABS)
Optical & Card
400 MHz microprocessor
32MB flash memory
BioBridge VX 10.0 only
88 x 88 x 25

200
500 
8 sets (max length 4-digits per password)
30000

Fingerprint, card or password
1
Any angles
Max 4-digits
< 1
< 0.0001
< 1

Yes (default)
Made to order

0 ~ 45
20 ~ 80
DC 12V 3A

Relay output/12VDC
NO only
Yes (NO/NC)

Yes (6 types):  • password only • card only • fingerprint only • fingerprint/card/password 
• card + password  • finge password 

Card

Fingerprint Password

SECURITY SETTINGS

ADJUST DOOR UNLOCK TIME

Adjust time for device to unlock according to your 
preference. 

Operation: 

Verify your Admin password > Press 4 > 

Green LED blinks > Buzzer emits long beep > Insert time 
in seconds, i.e. 10 > Green LED blinks > Buzzer emits long 
beep > Timer adjusted successfully

Note:

 The maximum unlock time is 254s. If you want to insert values 

less than 3-digits, hash (#) is required. I.e.: 10 will be keyed in as 10#. 

SELECT DOOR SENSOR TYPE 

Installing a door sensor is important to monitor door 
activity. Select the type (NO or NC) before it starts to work. 

Operation: 

Verify your Admin password > Press 0 > 

Green LED blinks > Buzzer emits long beep > Press 5 > 
Green LED blinks > Buzzer emits long beep > Press 
number to select type of door sensor > Green LED blinks 
> Buzzer emits long beep > Changes done successfully

Note:

 

 NO 

Type 

0

 NC 

Type 

1

 Disable 

door 

sensor 

2

OTHER OPERATIONS

RESET TO DEFAULT FACTORY SETTINGS

You can reset the device back to its default factory 
settings (including the default admin password, 1234). 

Operation: 

Dismantle device > Look for the tamper 

switch at the back of device > Wait for 30s > Buzzer emits 
long beep > Press and release the tamper switch 3 times 
> Install the device back to its position > Press the 
RESTART button (at the bottom of device)

UNLOCK DOOR ADMIN PASSWORD

On top of using the admin password as a key to start any 
operation, you can also use the admin password to 
unlock doors. 

Operation: 

Verify your Admin password > Press 0 > 

Green LED blinks > Buzzer emits long beep > Press 0 > 
Green LED blinks > Buzzer emits long beep > Door 
unlocked successfully 

ADJUST DOOR SENSOR DELAY TIME

Set time to allow door to remain open after unlocking. 
The device alerts you with a buzzer sound when the 
allowed time runs out. 

Operation: 

Verify your Admin Password > Green LED 

blinks > Buzzer emits long beep > Press 0 > Green LED 
blinks > Buzzer emits long beep > Press 4 > Green LED 
blinks > Buzzer emits long beep > Insert time in 
seconds, i.e. 10 > Green LED blinks > Buzzer emits long 
beep > Changes done successfully

Note: 

The maximum delay time is 254s. If you want to insert 

values less than 3-digits, hash (#) is required. I.e.: 10 will be keyed in 
as 10#. 

ENABLE ALARM OUTPUT FROM DEVICE

It is optional to link H3i to an alarm or siren to amplify 
its alerts. Make sure you enable the alarm output 
feature after linking up with the siren or alarm system. 

Operation: 

Verify your Admin password > Press 0 > 

Green LED blinks > Buzzer emits long beep > Press 1 > 
Green LED blinks > Buzzer emits long beep > Press 0 to 
enable > Green LED blinks > Buzzer emits long beep > 
Changes done successfully

Note: 

Press 1 to disable this feature if you do not want to link up 

H3i with an alarm or siren system. 

To turn off alarm output: Verify your Admin password > Press #

 

ENABLE ILLEGAL DISMANTLE ALARM

H3i will trigger the alarm or siren system immediately 
if somebody tries to dismantle it. 

Operation: 

Verify your Admin password > Green LED 

blinks > Buzzer emits long beep > Press 7 > Green LED 
blinks > Buzzer emits long beep > Press 0 > Green LED 
blinks > Buzzer emits long beep > Changes done 
successfully

Note: 

Press 1 to disable this feature if you do not want to use it. 

 

APPLY MULTI VERIFICATION METHOD

You can increase your access control’s security level by 
applying multiple verification methods. 

Operation: 

Verify your Admin password > Press 5 > 

Green LED blinks > Buzzer emits long beep > Insert 
number to represent the type of multi verification (as 
per table shown) > Green LED blinks > Buzzer emits 
long beep > Multi verification applied successfully

NUMBER MULTI 

VERIFICATION 

 1 

Password 

only

 2 

Card 

only

 3 

Fingerprint 

only

 4 

Fingerprint/card/password 

 

Card + Password 

 

Finge Password

ENABLE FAIL VERIFICATION ALARM

Enable device to trigger alarm or siren system when a 
user fails to verify more than 3 continuous times. 

Operation: 

Verify your Admin password > Press 0 > 

Green LED blinks > Buzzer emits long beep > Press 2 
> Green LED blinks > Buzzer emits long beep > Press 
0 > Green LED blinks > Buzzer emits long beep > 
Changes done successfully

Note: 

Press 1 to disable this feature if you do not want to use it.

?

ENABLE/DISABLE LED BLINKS DURING 
IDLE MODE

The LED on H3i will blink during verification. However, 
you can disable the LED blinks of the device during 
other operations. 

Operation: 

Verify your Admin password > Press 0 > 

Green LED blinks > Buzzer emits long beep > Press 3 > 
Press 0 (to enable) or 1 (to disable) > Green LED blinks > 
Buzzer emits long beep > Changes done successfully 