Access Control/Power Output Module

AN ALARM SIREN TO SECURE YOUR 

FINGERTEC® TERMINAL

For all FingerTec® door access control models, there is 
a security spring behind the terminal. During normal 
operation, the security spring is compressed and once 
the reader is dismantled, the spring will be released 
and “System broken” message will appear onscreen. 
During the release of the spring, the reader is out-
putting alarm signal. Nonetheless, no alarm sound is 
emitted because the reader is not equipped with pre-
installed siren.

To use the siren feature, we recommend you to install an additional alarm 
siren and connect it to FingerTec® terminals. 

BENEFITS OF USING ADAPTEC AC WITH ALARM SIREN

We recommend you to install terminal using AdapTec AC if you plan to 
use alarm siren. In AdapTec AC, an additional port is readily built to receive 
alarm signal from FingerTec® terminals. AdapTec AC is outputting DC12V 
and it is suitable to use with alarm siren that is having the same power 
input. You do not need to source additional DC12V power supply for this 
purpose. Furthermore, AdapTec AC provides a “Siren Accept” button where 
you can press the button to deactivate alarm siren when required.

FUNCTION • 

R2/M2, i-Kiosk100, i-Kiosk100 Plus ,Q2i and Kadex

Connect the terminal, alarm siren and AdapTec AC as below. Kindly set the 
jumper at the back of the terminal to support alarm signal type NC.

STEP 1 • 

Wiring Diagram

Summary of Contents for AdapTec AC

Page 1: ...DOOR LOCK TIM E R Installer Guide We Make Things Easy ...

Page 2: ...n Out reader system a system where two terminals control one entrance To support rechargeable backup battery compatible with any 12V re chargeable backup battery and to act as a backup power supply in the event of power failure To integrate with siren feature of the reader to alert user when termi nals is illegally dismantled Note AdapTec is compatible with NC type of siren with maximum 0 5A load ...

Page 3: ...cables ACCESS CONTROL POWER OUTPUT MODULE 1 Connect push button here if siren is installed during installation A press on the push button will turn off siren when the siren is trig gered 2 AdapTec may have broken and needs to be repaired 3 These are the power outputs from AdapTec Refer to the wiring dia grams in page 3 for details DOOR LOCK TIMER User can adjust the timing for the EM Lock and Drop...

Page 4: ...Accept Output Switch EXT Door To Battery Accept OK 12V MAX 0 5A Voltage Input I P Exit 0 0 0 12V 0 12V C NC 12V 0 Connection Points GND PWR COM NO NC GND AL AL BUT GND B B DC 12V Rechargeable Backup Battery WIRING DIAGRAMS AC900 TIME ATTENDANCE ONLY STEP 1 Connection Points STEP 2 Connect AdapTec AC to a Power Source STEP 3 Turn on the power to use the model for time attendance only ...

Page 5: ...L N E V V Power Supply Power Input Module EM Lock Emergency 2 Break Glass NC 3 ON OFF C Key Switch NC D Push Button AC110 240V L Live N Neutral E Earth R B G R Red B Blue G Green Connection Points WIRING DIAGRAMS AC900 ACCESS CONTROL ONLY OR TIME ATTENDANCE DOOR ACCESS STEP 1 Connection Points STEP 2 Connect AdapTec AC to a Power Source STEP 3 Turn on the power to use the AC900 for door access con...

Page 6: ...D SEN 485B 485A GND 232T 232R GND WD1 WD0 RJ45 1 RJ45 2 RJ45 3 RJ45 6 BELL BELL BEEP GLED RLED INWD0 INWD1 GND 12V L N E V V Power Supply Power Input Module AC110 240V L Live N Neutral E Earth R B G WIRING DIAGRAMS R2 M2 i Kiosk100 i Kiosk100 Plus Q2i and Kadex TIME ATTENDANCE ONLY STEP 1 Connection Points STEP 2 Connect AdapTec AC to a Power Source STEP 3 Now you can turn on the power source and ...

Page 7: ... BUT GND SEN EM Lock Emergency 2 Break Glass NC 3 ON OFF C Key Switch NC D Release Button 485B 485A GND 232T 232R GND WD1 WD0 RJ45 1 RJ45 2 RJ45 3 RJ45 6 BELL BELL BEEP GLED RLED INWD0 INWD1 GND 12V R B G WIRING DIAGRAMS R2 M2 i Kiosk100 i Kiosk100 Plus Q2i and Kadex ACCESS CONTROL ONLY OR TIME ATTENDANCE DOOR ACCESS STEP 1 Connection Points STEP 2 Connect AdapTec AC to a Power Source STEP 3 Turn ...

Page 8: ... 2 Break Glass NC 3 ON OFF C Key Switch NC D Release Button NO 2 COM 2 NC 2 SEN GND BUT NO 1 COM 1 NC 1 485 485 GND TXD RXD WD 0 WD 1 SGND GND 12V Connection Points in FingerTec Face ID2 R Red B Blue G Green WIRING DIAGRAMS Face ID 2 ACCESS CONTROL ONLY OR TIME ATTENDANCE DOOR ACCESS STEP 1 Connection points STEP 2 Connect AdapTec AC to a power source STEP 3 Turn on the power to use FingerTec Face...

Page 9: ...nput Module AC110 240V L Live N Neutral E Earth R B G NO 2 COM 2 NC 2 SEN GND BUT NO 1 COM 1 NC 1 485 485 GND TXD RXD WD 0 WD 1 SGND GND 12V DC 12V Rechargeable Backup Battery R Red B Blue G Green Connection Points in FingerTec Face ID2 WIRING DIAGRAMS Face ID 2 TIME ATTENDANCE ONLY STEP 1 Connection points STEP 2 Connect AdapTec AC to a power source STEP 3 Turn on the power to use FingerTec Face ...

Page 10: ... is emitted because the reader is not equipped with pre installed siren To use the siren feature we recommend you to install an additional alarm siren and connect it to FingerTec terminals BENEFITS OF USING ADAPTEC AC WITH ALARM SIREN We recommend you to install terminal using AdapTec AC if you plan to use alarm siren In AdapTec AC an additional port is readily built to receive alarm signal from F...

Page 11: ...TION AC900 For AC900 you will need to connect AC900 alarm siren and AdapTec AC as below FUNCTION Face ID 2 For Face ID 2 you will need to connect to alarm siren and AdapTec AC as below Reminder to deactivate alarm siren 1 You can deactivate the alarm siren by pressing push button that is connected to Siren Accept in AdapTec AC This action will turn off the alarm siren function in AdapTec AC Howeve...

Page 12: ...on the wall 3 Install the keyswitch as per instructions given in the box The keyswitch is an override key in case of system failure or break down 1 Drill 3 holes on the wooden door 2 Place Steel Bar on the door Insert the Silver Nut on one side and Al len Key Screw on the other side Tighten the screw to lock the Steel Bar onto its position 1 Drill 4 holes on the wooden frame Tighten the 4 screws t...

Page 13: ...240V Power Input 1 1 2 3 4 feet 1 2 meter recommended CEILING INDOOR Emergency Break Glass Push Button 4 5 6 1 12V 3A DC Power Out put 2 AdapTec AC Note RefertoAdapTecuser guide for wiring diagrams 3 12V Rechargeable Bat tery Note It is recommended to place 1 2 and 3 out of sight either above a ceiling or wall mounted Emergency Break Glass and Push Button should be installed indoor These two items...

Page 14: ...ll 3 Install the keyswitch as per instructions given in the box The keyswitch is an override key in case of system failure or breakdown 1 Lodge the U Bracket into the upper edge of the glass doorframe Tighten the 4 Allen Screws to hold the U Bracket into position 2 Place the Steel Bar on the side of the U Brack et Tighten the Philip Screw to lock the Steel Bar onto position 1 Drill 4 holes on the ...

Page 15: ...eries AdapTec AC ON OFF Keyswitch To FingerTec Series 12V Rechargeable battery AC110 240V Power Input 4 5 6 1 12V 3A DC Power Out put 2 AdapTec AC Note Refer to AdapTec user guide for wiring diagrams 3 12V Rechargeable Battery Note It is recommended to place 1 2 and 3 out of sight either above a ceiling or wall mounted Emergency Break Glass and Push Button should be installed indoor These two item...

Page 16: ...Remove the L shape piece from the AdapTec AC Find an L shape piece at the top right of an AdapTec AC This piece is attached to the AdapTec AC by 2 screws Attach the L shape to the AdapTec AC as shown and tighten the screws Open the cap look for the part shown in the diagram and you will see 2 holes www fingertec com 2010 FingerTec Worldwide Sdn Bhd All rights reserved Printed in Malaysia 042010 In...

Reviews: