background image

PV, SV

Power 
ON

Input Type Menu

Input Signal Option

Alarm soft activation

All can with Hysteresis and de-energized function for 
ON/OFF control

ALARM MODE SETTING

ON

OFF

(           )

Deviation high alarm

ON

OFF

(           )

Deviation high alarm

ON

OFF

Deviation low alarm

(           )

ON

OFF

(           )

Deviation low alarm

ON

ON

OFF

Deviation high/low alarm

(           )

OFF

OFF

ON

Band alarm

(           )

ON

OFF

Process high alarm

(           )

(           )

ON

OFF

Process low alarm

: Alarm Setting Value

: Hysteresis Setting Value

: SV     

Press       to show ALM option

Press       to enter  Alarm  option

Press       to enter  setting mode

Press       to shift to two 
digit  position

Press       to set 5.0 value 

Press       to confirm

Press       twice back to main screen

*There  are  eight  different  Alarm  modes,
  please refer Alarm mode setting table.

Press       to save setting

Press       to enter SV setting
mode

Press       to Modifd

Press       to shift to four digit
position

Press       to set 100.0

*

Flashing SV indicate  that 

  Auto Tune  is executing.

Press       twice  back to 
main screen

Press       three time

Press       to enter contrl option

Press       to enter setting mode

Press       to choose PID mode

Press       to save setting

Press       to show TUN option 

Press       to enter setting mode

Press       to choose  TUN

Press       to confirm

SETTING PRECEGURE DIAGRAM

PROGRAM SETTING FLOWCHART

Press       at least 5sec to enter 

Manual control

PV

 Out1 MV setting

 Out2 MV setting

: Out1, Out2, and PV value 
  cross indication

: MV value adjustment

: Press and hold for 3 seconds to 
  return to the standard mode.  

While in modifying:

:Increment

:Save setting

:Decrease

Alarm  Relay Direction 1

Alarm Relay Position 1

Alarm Relay Hysteresis 1

Alarm Relay Delay Time 1

Alarm Relay Style 1

Alarm Relay Position 2

Alarm Relay Hysteresis  2

Alarm Relay Delay Time 2

Alarm  Relay Direction 2

Alarm Relay Style 2

Limit Lo (Min. Value of SV range) 

?

Limit  Hi (Max. Value of SV range)

Set Value SV

Decimal point set

Scale upper limit value

Scale lower limit value 

I Value 

ONOFF/PID

Operation 

Auto 

 Tuning 

PV input bias

SV offset value during 
auto tuing

P  Value

D Value 

Manual Reset 

Input digital Filter 

Heater is controlled by out1
Cooler is controlled by out1

Device ID No.

Baud Rate

Hex
Ascii

Press        and        hold for 3 seconds

Hold temperature 
Over/ below room 

     Tempereture 

Lock Label 

Password protection

Quick SV setup protection 

Allow entry manual mode

EEPROM protection

Default to factory setting

Sceen return time (S)

Heater is controlled by out 2
Cooler is controlled by out 2

Cycle Time 1 (Second) 

Cycle Time 2 (Second) 

Control output Hysteresis 1

Control output Hysteresis 2

Deadband control

Loop break alarm

Deadband parameter of Heater

Deadband parameter of cooler

If SV=100, the setup procedure is as below: 

1.Quick Setup

2.

 

Auto Tuning

3.

 

Alarm Setting

Made in taiwan

8 data bit ; No Parity ; 1 Stop Bits
8 data bit ; No Parity ; 2 Stop Bits
8 data bit ; Odd Parity ; 1 Stop Bits
8 data bit ; Even Parity ; 1 Stop Bits

Control output direct/ reverse 
operation 2 

Control output direct/ reverse 
operation 1

Press

to show alarm 

position 1 option

        

 

* Input Type: Please refer to "input type menu" on reverse side of the manual.
* Temperature input type and decimal display: Please refer to " input signal option" 
  on reverse side of the manual.
  (Decimal point display depends on the choosen input signal type) 