PV, SV
Power
ON
Input Type Menu
Input Signal Option
Alarm soft activation
All can with Hysteresis and de-energized function for
ON/OFF control
ALARM MODE SETTING
ON
OFF
( )
Deviation high alarm
ON
OFF
( )
Deviation high alarm
ON
OFF
Deviation low alarm
( )
ON
OFF
( )
Deviation low alarm
ON
ON
OFF
Deviation high/low alarm
( )
OFF
OFF
ON
Band alarm
( )
ON
OFF
Process high alarm
( )
( )
ON
OFF
Process low alarm
: Alarm Setting Value
: Hysteresis Setting Value
: SV
Press to show ALM option
Press to enter Alarm option
Press to enter setting mode
Press to shift to two
digit position
Press to set 5.0 value
Press to confirm
Press twice back to main screen
*There are eight different Alarm modes,
please refer Alarm mode setting table.
Press to save setting
Press to enter SV setting
mode
Press to Modifd
Press to shift to four digit
position
Press to set 100.0
*
Flashing SV indicate that
Auto Tune is executing.
Press twice back to
main screen
Press three time
Press to enter contrl option
Press to enter setting mode
Press to choose PID mode
Press to save setting
Press to show TUN option
Press to enter setting mode
Press to choose TUN
Press to confirm
SETTING PRECEGURE DIAGRAM
PROGRAM SETTING FLOWCHART
Press at least 5sec to enter
Manual control
PV
Out1 MV setting
Out2 MV setting
: Out1, Out2, and PV value
cross indication
: MV value adjustment
: Press and hold for 3 seconds to
return to the standard mode.
While in modifying:
:Increment
:Save setting
:Decrease
Alarm Relay Direction 1
Alarm Relay Position 1
Alarm Relay Hysteresis 1
Alarm Relay Delay Time 1
Alarm Relay Style 1
Alarm Relay Position 2
Alarm Relay Hysteresis 2
Alarm Relay Delay Time 2
Alarm Relay Direction 2
Alarm Relay Style 2
Limit Lo (Min. Value of SV range)
?
Limit Hi (Max. Value of SV range)
Set Value SV
Decimal point set
Scale upper limit value
Scale lower limit value
I Value
ONOFF/PID
Operation
Auto
Tuning
PV input bias
SV offset value during
auto tuing
P Value
D Value
Manual Reset
Input digital Filter
Heater is controlled by out1
Cooler is controlled by out1
Device ID No.
Baud Rate
Hex
Ascii
Press and hold for 3 seconds
Hold temperature
Over/ below room
Tempereture
Lock Label
Password protection
Quick SV setup protection
Allow entry manual mode
EEPROM protection
Default to factory setting
Sceen return time (S)
Heater is controlled by out 2
Cooler is controlled by out 2
Cycle Time 1 (Second)
Cycle Time 2 (Second)
Control output Hysteresis 1
Control output Hysteresis 2
Deadband control
Loop break alarm
Deadband parameter of Heater
Deadband parameter of cooler
If SV=100, the setup procedure is as below:
1.Quick Setup
2.
Auto Tuning
3.
Alarm Setting
Made in taiwan
8 data bit ; No Parity ; 1 Stop Bits
8 data bit ; No Parity ; 2 Stop Bits
8 data bit ; Odd Parity ; 1 Stop Bits
8 data bit ; Even Parity ; 1 Stop Bits
Control output direct/ reverse
operation 2
Control output direct/ reverse
operation 1
Press
to show alarm
position 1 option
* Input Type: Please refer to "input type menu" on reverse side of the manual.
* Temperature input type and decimal display: Please refer to " input signal option"
on reverse side of the manual.
(Decimal point display depends on the choosen input signal type)