52
2. Clean the solar radiation sensor every 3 months with water and towel.
3. Replace batteries every 2 to 3 years.
10.1
Advanced Rain Gauge Cleaning
If the rain gauge stops updating, it is possible for spiders and other insects to
nest inside the sensor array housing and interfere with the rain gauge
mechanism.
1. Remove the six screws on the bottom of the sensor array..
2.
CAREFULLY
separate the top housing from the bottom housing. They
cannot be completely separated due to wires.
DO NOT STRESS THE
WIRES
. Open the sensor housing slightly, like a clam shell.
3. Clean any debris and spider webs, as shown in below figure.