background image

 

 

14 

Wind direction can be adjusted by 0-359

°

.For southern hemisphere installations, the wind 

direction need to change by 180

°

 

j) 

WIND FACTOR   

Wind speed calibration coefficient: default 1 (range is Range is 0.1-2.5)   

 

k)  RAIN FACTOR   

Rain factor calibration coefficient: default 1 (range is Range is 0.1-2.5)     

 

l) 

RAIN DAY CORRECT   

Calibration for total rain falls of 1 day. (Range is 0-9999mm) 

 

m)  RAIN WEEK CORRECT   

Calibration for total rain falls of 1 week (Range is 0-9999mm) 

 

n)  RAIN MONTH CORRECT   

Calibration for total rain falls of 1 month (Range is 0-9999mm) 

 

o)  RAIN YEAR CORRECT   

Calibration for total rain falls of 1 year (Range is 0-9999mm) 

 

p)  RAIN TOTAL CORRECT   

Calibration for total rain falls since last reset. (Range is 0-9999mm) 

 

 

Transmitter ID 

Display the transmitter ID. 

 

2.2 ALARM SETTING MODE 

In  normal  mode,  press  ALARM  key  you  will  enter  high  alarm  mode,  and  press  ALARM  key 

again you will switch to low alarm mode. 

 

 

HIGH ALARM SETTING 

Press 

/

  key to transfer among the different segments and press 

/   key to adjust the 

value of the high alarm. 

 

a)  TIME ALARM 

–Set time alarm. 

b)  LIGHT HIGH ALARM --Set light high alarm   

c)  UVI HIGH ALARM --Set UVI high alarm   

d)  In TEMP HIGH ALARM --Set indoor temperature high alarm   

e)  In HUMI HIGH ALARM --Set indoor humidity high alarm 

f) 

Out TEMP HIGH ALARM Set outdoor temperature high alarm 

g)  Out HUMI HIGH ALARM Set outdoor humidity high alarm 

h)  ABS BARO HIGH ALARM --Set absolute barometric pressure high alarm 

i) 

REL BARO HIGH ALARM --Set relatively barometric pressure high alarm   

j) 

WIND HIGH ALARM --Set wind speed high alarm   

k)  GUST HIGH ALARM --Set gust speed high alarm 

Summary of Contents for WH18B

Page 1: ...the barometric pressure because the air pressure is pushing equally in every direction RELATIVE AIR PRESSURE Relative air pressure is the same as the barometric pressure The calculation of relative a...

Page 2: ...ded Features Time and date Moon phase Indoor temperature and humidity Outdoor temperature and humidity Wind chill wind direction Rainfall Display rain level and rainfall data in 24 hours one week one...

Page 3: ...he remote sensor will be light up for 3 4 seconds If no LED light up or is lighted permanently make sure the battery is inserted the correct way or a proper reset is happened 2 When the base station i...

Page 4: ...ge of each other or repeat the battery installation procedure Note Commonly the radio communication between receiver and transmitter in the open field can reach a distance of up to 330 feet providing...

Page 5: ...5 Anemometer wind direction sensor Mounting the dual wind sensor holder Mounting the rain sensor Thermo hygro sensor with solar panel...

Page 6: ...put marked Rain on the thermo hygro sensor The solar transmitter The solar transmitter makes use of solar energy to power the instruments they are connected to Note It use AA size alkaline rechargeabl...

Page 7: ...mp 10 RF signal 11 Memory status 12 Wind direction 13 Rain fall 14 Wind speed 15 Dew point 16 Outdoor humidity 17 Outdoor Temperature 18 UV 19 Light 20 Date 2 Initial Display Console Set Up 2 1 The un...

Page 8: ...the alarm MAX MIN Display the MAX MIN value Increase the setting parameter Move to next message of the selected segment on the message panel Decrease the setting parameter Move to previous message of...

Page 9: ...current section is RAIN you can press SET key to select among RAIN RATE RAIN EVENT DAY WEEK MONTH YEAR and TOTAL 1 Quick Display Mode Update every 5 Seconds In the normal mode and once some segment is...

Page 10: ...ill display transmitter ID for 120 second Light and UVI a The max light of the day b The max light since last reset c The max UVI of the day d The max UVI since last reset Indoor temperature a The max...

Page 11: ...nd gust speed a The max wind speed of the day b The max wind speed since last reset c The max gust of the day d The max gust since last reset Wind chill dew point heat index a The max of dew point hea...

Page 12: ...Press key to transfer the unit or change the value Hold the key for 2 seconds will increase decrease digits in great steps Press HISTORY key or wait for 30 seconds at any time device will return to no...

Page 13: ...is the brighter the display is KEY BEEP ON OFF Register new transmitter REREGISTER ON OFF Calibration setting a LIGHT FACTOR LUX index calibration coefficient default 1 Range is 0 1 10 b UV FACTOR UV...

Page 14: ...st reset Range is 0 9999mm Transmitter ID Display the transmitter ID 2 2 ALARM SETTING MODE In normal mode press ALARM key you will enter high alarm mode and press ALARM key again you will switch to l...

Page 15: ...ll still flash until the weather data doesn t meet the user set alarm level 3 Max Min Mode In Normal Mode press the MIN MAX key to enter the max min mode Press MIN MAX select today max history max tod...

Page 16: ...m Wind chill temperature h DEW POINT TODAY MIN DEW POINT TOTAL MIN Minimum Dew point temperature Each Maximum minimum value can be cleared by pressing SET key for 2 seconds during this mode Press the...

Page 17: ...LL MOON WANING GIBBOUS MOON LAST QUARTER MOON WANING CRESCENT MOON Beaufort Scales Wind Speed Wind speed Beaufort number Description 0 1mph 0 1 6kph 0 Calm 1 3mph 1 6 4 8kph 1 Light air 3 7mph 4 8 11...

Page 18: ...rainfall event 24H WEEK MONTH YEAR default RAINFALL RATE 18 Rainfall of year season begin default JAN 19 Time alarm 0 00 23 59 default 0 00 disable 20 Indoor temperature high alarm 40 0 60 0C 14F 140...

Page 19: ...e thermo hygrometer transmitter LED for flashing You must remove the radiation shield to view the LED The outside sensor has an LED under the plastic just above the battery compartment The LED will fl...

Page 20: ...ensor and remote closer together 3 If the sensor assembly is too close less than 5 move the sensor assembly away from the display console 4 Make sure the remote sensors are not transmitting through so...

Page 21: ...rresponds to an altitude of 2 200 to 2 700 feet At higher altitudes expect some non linearity or error Time is incorrect Make sure your time zone and daylight savings time setting is correct The forec...

Page 22: ...ected by USB cable 3 0 Installation of the WeatherSmart Software Firstly the Base Station and the Outdoor Sensors should be connected and checked for correct function see Operation Manual for Professi...

Page 23: ...o make any setting changes on the PC software However you can still easily make any setting changes you wanted from the PC and download the changes into the base station the setting change will be ref...

Page 24: ...tem button enters the Setting menu This section is used to set up PC software display base station units Once you made your choice press Save to make the setting effective 4 1 2 Click Alarm button ent...

Page 25: ...le the corresponding alarm function Once you made your choice choose Save to make the setting effective If you don t want to make any change just press Cancel and exit without change 4 1 3 Click Max M...

Page 26: ...x Min menu This section is used to display the recorded min and max value recorded with time stamp Min Max reset can only be done through key operation on the base station 4 1 5 Click Language button...

Page 27: ...When memory on base station is full press Clear Memory button to refresh the memory space on the base station remember to upload all data before pressing this button If you wanted to start a new weat...

Page 28: ...can see the history data plotted in graph format for easier observation If you want to see more details just use your mouse to select the area you wanted and the display will be automatically updated...

Page 29: ...with this software To make the graph function working properly please check the following step 1 find the folder where the WeahterSmart exe file is located 2 Create a file name reg_graph bat file with...

Page 30: ...rt Version 1 8 or greater 4 3 1 Select Upload Wunderground com from the menu bar User can upload data to website www wunderground com or their own website If user choose www wunderground com he do not...

Page 31: ...st register on the Wunderground com website Registration is free Note How to create a Wunderground com account and station ID 1 Join the Wunderground com Community Visit https www wunderground com mem...

Page 32: ...Join the Personal Weather Station PWS network Visit http www wunderground com personal weather station signup or select More Register Your PWS from the menu at the top of the WeatherUndeground com web...

Page 33: ...and select Auto Upload checkbox and Save Please Note Make sure you enter the ID in all capitals and the password exactly as you chose it both fields are case sensitive 4 3 2 Upload to WeatherBug Sele...

Page 34: ...u do not have an account 2 Once registered with Weatherbug com you will need to sign up your station To get started visit http backyard weatherbug com group backyardstations page backyardstations Ente...

Page 35: ...click the WeatherSmart software icon the main interface as below will be opened The functions of MAC OS are the same to the windows version Once the device is connected to MAC PC by USB cable setting...

Page 36: ...36 5 1 Setting option Please refer to 4 1 1 5 2 Alarm option Please refer to 4 1 2 5 3 Max Min option...

Page 37: ...37 5 4 History option Please refer to 4 2 1 5 5 Graph Please refer to 4 2 2...

Page 38: ...38 5 6 Upload option Please refer to 4 3 5 7 Check software version...

Page 39: ...und to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential...

Page 40: ...delete or change any image whether or not purposely uploaded onto the server by a user of the touch screen weather station and the WeatherSmart software products The WeatherSmart software products are...

Reviews: