background image

 

Note: 

 

Please participate in the preservation of the environment by properly 
disposing of all used-up batteries and accumulators at designated disposal 
points. Never dispose of batteries in a fire as this may cause explosion, risk of 
fire or leakage of dangerous chemicals and fumes 

 

 

2.2 Mounting 

2.2.1  Base Station 

With one foldable legs at the back of the unit, the base station can be placed onto 
any flat surface or wall mounted at the desired location by the hanging holes at 
the back of the unit. It is important to check that the radio signal can be received 
before permanently mounting any of the units 

2.2.2  Remote Sensor 

                           

 

FRONT VIEW                                      BACK VIEW 

- 5 -

Summary of Contents for WH1285

Page 1: ...ATOR 9 3 5 ICE ALERT 9 3 6 COMFORT INDEX 9 4 PROGRAM MODE 10 4 1 SETTING MODE 10 4 2 ALARM MODE 11 4 3 MIN MAX MODE 11 4 4 Channel Mode 11 5 TROUBLESHOOTING 12 6 SPECIFICATION 13 This Operation Manual...

Page 2: ...a safe place for future reference It contains important notes on setup and operation 1 1 Package Contents z 1x Weather station base unit z 1x remote Sensor with mounting bracket z Mounting screws z I...

Page 3: ...dom security code is transmitted and this code must be synchronized with the base station to receive weather data 3 Wait 3 minutes or until the outdoor temperature is displayed in the weather station...

Page 4: ...inue to scan for the radio controlled time signal each day at 2 00 8 00 12 00 and 20 00 despite it being manually set If reception has been unsuccessful then the radio controlled time icon will not ap...

Page 5: ...isk of fire or leakage of dangerous chemicals and fumes 2 2 Mounting 2 2 1 Base Station With one foldable legs at the back of the unit the base station can be placed onto any flat surface or wall moun...

Page 6: ...sensors is under the eaves Avoid mounting remote sensor in direct sunlight obstacles such as walls concrete and large metal objects will reduce the range To wall mount use 3 screws to affix the wall...

Page 7: ...base station low battery indicator 10 number showing sensor unit 11 outdoor temperature display 12 temperatuer unit 13 date day of week 14 alarm icon 15 alarm time 16 MIN MAX icon 17 differential baro...

Page 8: ...However if the icon displayed is a sun or raining cloud there will be no change of icon if the weather gets any better with sunny icon or worse with rainy icon since the icons are already at their ex...

Page 9: ...l be upward if the air pressure continuous decreasing 3 times the arrow will be downward otherwise the tendency arrow will not show up 3 4 Storm warning indicator The storm waning pressure threshold c...

Page 10: ...mode In the setting mode press the SET key to select the following setting in sequence press CH key to select the units or scrolls the value Press MIN MAX key to decrease the value 1 Five language sel...

Page 11: ...s will flash to set the desired hour by using the CH or MIN MAX keys Press the SET key again the alarm minute digits will flash to set the desired minute by using the CH or MIN MAX keys Press the SET...

Page 12: ...n 2 of this manual 1 4 This problem could also be a result of radio interference in your neighborhood try relocating the sensor and the base station Q 2 Remote sensor drops off intermittently A Possib...

Page 13: ...y 20 99 Resolution 1 Indoor data Measuring interval of temperature 60 sec Measuring interval of Pressure 10 minutes Indoor temperature range 10 to 60 Resolution 0 1 Measuring range air pressure 300hPa...