Fine Offset Electronics WH1081PC Operation Manual Download Page 6

 

- 6 - 

Note:

 Commonly the radio communication between receiver and transmitter in the open field can reach a 

distance of up to 330 feet providing that there are no interfering obstacles such as buildings, trees, 
vehicles, high voltage lines, etc.       
Radio interferences such as PC screens, radios or TV sets can, in bad cases, entirely cut off radio 
communication. Please take this into consideration when choosing standing or mounting locations.       

   

Setting Up 

 

 

Note:

 Because of the default settings already determined by the manufacturer it may not be necessary for the 

majority of users to perform – except the Relative Air Pressure (see further down) - any further basic 
settings. Changes, however, can be easily made.   

   
For basic settings, the following menu is started by touching the Touch Screen in the desired display area.     
     
  The basic settings can now be performed in the following successive order:       

 

Note: setting procedure can be exited at any time by touching any other function area (except 
“+”, “-” or “ON/OFF”). 
 

indoor temperature 

 

 

Activate the indoor temperature related setting by       
1)Touch the INDOOR TEMPERATURE section, 

+

 button and 

 button will be flashing. Touch the 

+

 button or 

 button to Shift the display unit between 

 and 

   

2)Touch the INDOOR TEMPERATURE section again to set the indoor temperature high alarm 

function, the 

+

, ON/OFF and 

 button will be flashing, HI AL icon will light up. Touch the

+

 button 

or 

 button to change the value, hold the

+

 button or 

 button for 3s to change the number in 

great step. Touch the ON/OFF button to choose the alarm on or off (if alarm is enabled, the 
speaker icon will be turned on indicating the alarm function has been enabled). 

3)Touch the INDOOR TEMPERATURE section the third time to set the indoor temperature low 

alarm function, the 

+

, ON/OFF and 

 button will be flashing, LO AL icon will light up. Touch the

+

 

button or 

 button to change the value, hold the

+

 button or 

 button for 3s to change the 

number in great step. Touch the ON/OFF button to choose the alarm on or off (if alarm is 
enabled, the speaker icon will be turned on indicating the alarm function has been enabled). 

4)Touch the INDOOR TEMPERATURE section the fourth time to display maximum indoor 

temperature record, the maximum records will be flashing, MAX icon will light up as well. Hold 
the flashing max value for 3s, the maximum value will be reset to current reading. 

5)Touch the INDOOR TEMPERATURE section the fifth time to display minimum indoor 

temperature record, the minimum records will be flashing, MIN icon will light up as well. Hold the 
flashing min value for 3s, the minimum value will be reset to current reading. 

 

outdoor temperature 

Summary of Contents for WH1081PC

Page 1: ...ure is a combination of the absolute air pressure and the altitude ABSOLUTE AIR PRESSURE Absolute air pressure is the actual air pressure on the barometer without regard to altitude INCHES OF MERCURY...

Page 2: ...y slightly touching not pressing the related areas touch the flashing ON OFF or to make the corresponding selection or increase the value Every time a programming step is activated by touching a switc...

Page 3: ...3 Getting Started Setup Sensors...

Page 4: ...4...

Page 5: ...l be turned on for 4 seconds then it will be off and start to work normally The transmitter will make a data transmission When there is a data transmission happened the LED will be on for 20ms After i...

Page 6: ...the INDOOR TEMPERATURE section again to set the indoor temperature high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value h...

Page 7: ...ourth time to set the outdoor temperature low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold the button or button fo...

Page 8: ...alue for 3s the minimum value will be reset to current reading Outdoor humidity Procedures and settings are similar to Indoor humidity Wind speed Activate the wind related setting by 1 Touch the WIND...

Page 9: ...the alarm function has been enabled 4 Touch the rain section the fourth time to display current maximum rain fall record Touch the rain section for 3s will reset the maximum rain fall value to curren...

Page 10: ...hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm f...

Page 11: ...hour Hold the button or button for 3s to change the number in great step 7 Touch the DATE section the seventh time button and button will be flashing Touch the button or button to set alarm minute Hol...

Page 12: ...imum 4080 data sets of the Weather Station is only limited by the capacity of the PC s main memory PC software installation The installation of WH1081PC software is very simple double click the setup...

Page 13: ...C 40 to 149 Resolution 0 1 C 0 2 Measuring range rel humidity 10 99 Rain volume display 0 9999mm show OFL if outside range Resolution 0 3mm if rain volume 1000mm 1mm if rain volume 1000mm Wind speed...

Page 14: ...orized depot All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permiss...