Fine Offset Electronics WH1081PC Operation Manual Download Page 10

 

- 10 - 

 

 

1)Touch the PRESSURE section, 

+

 button and 

 button will be flashing. Touch the 

+

 button or 

 

button to Shift the display between Absolute pressure and Relative pressure. 

2)Touch the PRESSURE section again, 

+

 button and 

 button will be flashing. Touch the 

+

 button 

or 

 button to Shift the display unit between hPa, inHg and mmHg. 

3)Touch the PRESSURE section the third time to set the Relative Pressure value. The 

+

 and 

 

button will be flashing, rel icon will light up. Touch the

+

 button or 

 button to change the value, 

hold the

+

 button or 

 button for 3s to change the number in great step. 

4)Touch the PRESSURE section the forth time to set the pressure high alarm function, the 

+

ON/OFF and 

 button will be flashing, HI AL icon will light up. Touch the

+

 button or 

 button to 

change the value, hold the

+

 button or 

 button for 3s to change the number in great step. Touch 

the ON/OFF button to choose the alarm on or off (if alarm is enabled, the speaker icon will be 
turned on indicating the alarm function has been enabled). 

5)Touch the PRESSURE section the fifth time to set the pressure low alarm function, the 

+

ON/OFF and 

 button will be flashing, LO AL icon will light up. Touch the

+

 button or 

 button to 

change the value, hold the

+

 button or 

 button for 3s to change the number in great step. Touch 

the ON/OFF button to choose the alarm on or off (if alarm is enabled, the speaker icon will be 
turned on indicating the alarm function has been enabled). 

6)Touch the PRESSURE sections the sixth time to display maximum pressure record, to display 

maximum pressure, the recorded maximum value will be flashing, MAX icon will light up as well. 
Hold the maximum value for 3s, the maximum value will be reset to current reading. 

7)Touch the PRESSURE section the seventh time to display minimum pressure record, to display 

minimum pressure record, the recorded minimum value will be flashing, MIN icon will light up as 
well. Hold the minimum value for 3s, the minimum value will be reset to current reading. 

 
Note: when absolute pressure is selected, step 3 will be skipped since absolute pressure is 
selected for display.   
 

Pressure bar graph 

Touch the PRESSURE BAR GRAPH section and then press + or – to toggle the bar graph 
time scale between 12hrs or 24 hrs for pressure history.   
 

Time 

 

 
1) 

Touch the TIME section, 

+

 button and 

 button will be flashing. Touch the 

+

 button or 

 button 

to adjust the contrast level from 0 to 8. (default 5) 

2)

Touch the TIME section again, 

+

 button and 

 button will be flashing. Touch the 

+

 button or 

 

button to set the timezone. 

3)Touch the TIME section the third time, 

+

 button and 

 button will be flashing. Touch the 

+

 button 

Summary of Contents for WH1081PC

Page 1: ...ure is a combination of the absolute air pressure and the altitude ABSOLUTE AIR PRESSURE Absolute air pressure is the actual air pressure on the barometer without regard to altitude INCHES OF MERCURY...

Page 2: ...y slightly touching not pressing the related areas touch the flashing ON OFF or to make the corresponding selection or increase the value Every time a programming step is activated by touching a switc...

Page 3: ...3 Getting Started Setup Sensors...

Page 4: ...4...

Page 5: ...l be turned on for 4 seconds then it will be off and start to work normally The transmitter will make a data transmission When there is a data transmission happened the LED will be on for 20ms After i...

Page 6: ...the INDOOR TEMPERATURE section again to set the indoor temperature high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value h...

Page 7: ...ourth time to set the outdoor temperature low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold the button or button fo...

Page 8: ...alue for 3s the minimum value will be reset to current reading Outdoor humidity Procedures and settings are similar to Indoor humidity Wind speed Activate the wind related setting by 1 Touch the WIND...

Page 9: ...the alarm function has been enabled 4 Touch the rain section the fourth time to display current maximum rain fall record Touch the rain section for 3s will reset the maximum rain fall value to curren...

Page 10: ...hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm f...

Page 11: ...hour Hold the button or button for 3s to change the number in great step 7 Touch the DATE section the seventh time button and button will be flashing Touch the button or button to set alarm minute Hol...

Page 12: ...imum 4080 data sets of the Weather Station is only limited by the capacity of the PC s main memory PC software installation The installation of WH1081PC software is very simple double click the setup...

Page 13: ...C 40 to 149 Resolution 0 1 C 0 2 Measuring range rel humidity 10 99 Rain volume display 0 9999mm show OFL if outside range Resolution 0 3mm if rain volume 1000mm 1mm if rain volume 1000mm Wind speed...

Page 14: ...orized depot All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permiss...

Reviews: