background image

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

θmax=26°

-20-

2977

744

331

186

119

83

430

107

48

27

17

12

299

75

33

19

12

8

107

27

12

7

4

3

742

186

82

46

30

21

735

234

104

38

37

26

272

68

30

17

11

8

255

64

28

16

10

7

2.27

4.55

6.82

9.09

2.50

5.01

7.51

10.02

2.46

4.91

7.37

9.83

2.33

4.67

7.00

9.34

2.48

4.96

7.44

9.92

2.32

4.65

6.97

9.30

2.31

4.63

6.94

9.25

2.31

4.63

6.94

9.25

11.36

13.64

12.52

15.02

12.28

14.74

11.67

14.01

12.40

14.88

11.62

13.94

11.57

13.88

11.57

13.88

2m

4m

6m

8m

10m

12m

14m

14m

12m

10m

8m

6m

4m

2m

0m

Spot dia(m)

Spot dia(m)

Spot dia(m)

Spot dia(m)

Spot dia(m)

Spot dia(m)

Spot dia(m)

Spot dia(m)

Spot dia(m)

Vertical

W

(

)

lux

RylB

(

)

lux

B

(

)

lux

BluG lux

(

)

G

(

)

lux

OrgR

(

)

lux

R

(

)

lux

Ambr

(

)

lux

Summary of Contents for FINE 3160 DG

Page 1: ...l user friendly design Compliant with CE and support international standardized DMX512 The light source comprised of high intensity 3W LED chips can achieve homogeneous and pure color mixing output through delicate arrangement of LEDs These LEDs are controlled via an on board microprocessor and supplied with an accurate constant current controlling mode The brightness of each LED can vary from a m...

Page 2: ...1 fixture exploded drawing Appendix 2 FINE 3160 DG illuminance diagram Appendix 3 FINE 3160 DG wiring diagram 2 4 2 1Fixture profile dimensions 4 2 2Fixture introduction 5 6 3 1Included items 6 6 7 5 1DMX512 connection 7 8 6 1Fuses 8 6 2Power connection 8 9 7 1Control panel introduction 9 12 8 1Production feature explanation 12 12 9 1Menu control 12 9 2DMX control 13 14 10 Ordering P N ...

Page 3: ...s possible This fixture is intended for professional use only When operating the fixture attentions should be drawn to fire electric shock hazards and lethal injuries caused by fall Read this User Mannual before mounting and ennergizing the fixture Observe the safety guideline and notice the warnings both in this User Mannual and on the fixture Yet any safety concerns not covered hereby contact th...

Page 4: ...tificate Make sure that the mains power supply you use is up to local construc tion and electronic code regulation the over load protection reliable earthing is essential Each fixture must be grounded correctly and be installed according to related regulation Disconnect the fixture from mains supply before replacing any fuse Avoid using the fixture in damp environment 3 Protection against burning ...

Page 5: ... 4 2 1 Fixture profile dimensions Front view Side view 2 ...

Page 6: ...n example below Front view Rear view LED cooling housing LED lens Hanger Bracket Grating plate Adjusting bolt Arc plastic handle Foot pad 1 2 3 4 5 6 7 7 4 5 Cooling fan Power output Power input DMX output Display Control button DMX input 9 10 11 12 13 14 15 ...

Page 7: ...heck that please contact the professional person Wrong installation will result in fatal hazard The fixture working ambient temperature are between 20 45 When ambient temperature over the range don t operate the fixture When the fixture are in installtion teardown remove or servicing don t stand in under the fixture Operator must be insure the fixture are safely connected The input power supply mu...

Page 8: ...e of grating plate faces outwards 2 The grating plate can be replaced by any other secondary optics Fig 4 1 3 Housing assembled with grating plate Tips for data link 5 1 DMX512 connection Note The signal cable was type X connection Type X connection if the external flexible cable or cord of this fixture is damaged it shall be replaced by a special cord or cord exclusively available from the manufa...

Page 9: ...aid first fixture to the 3 pin input of a second fixture Similarly repeat the above connection step and end the data link with a plug in terminator Shown as Fig 5 1 2 below Controller Terminator If long distance data transfer occurs a DMX512 signal amplifier is necessary The added amplifier is inserted between the lighting controller and the first fixture on the basis of a normal data link Fig 5 1...

Page 10: ...se it will destroy the equipment The fixture is provided with sta ndard 2 pin socket Please according to table 6 2 1 connect to power supply Yellow green line must be earthed If you still have any question to the install ation please consultant with the experienced electrician Color Brown Blue Yellow Green Wire Live Neutral Earth Mark L N 7 Control panel 7 1 Control panel introduction 1 Mains outp...

Page 11: ...fine tuning Show routine Color temperature low to high opt opt opt func func func func func func func opt opt opt opt opt opt opt opt opt opt opt opt opt opt func func func func func func func func func func func func func func func sub Mode Ch05 Ch06 Ch08 Ch11 Ch12 Option 5 channel mode high luminance HSI mode Option 6 channel mode high chroma HSI mode Option 8 channel mode Option 11 channel mode...

Page 12: ...e Control enabled Temperature Control disabled func func func func sub Stub 000 009 010 250 250 254 255 255 No strobe function 1 25Hz 25Hz LED on without strobe func sub TEST Off On All LED off All LED on Ver XXXX func sub Display version number ...

Page 13: ... input output 3 pin XLR connector Protection against over current over voltage over heat 7 colors variable strobes rainbow effect independent dimming brightness controlling scale 0 256 rich colors and effects free of flicker Housing material aluminum alloy Color standard color black other colors available on request Protective ratting IP20 Weight 27 4KG Size 544X370X487 mm Compliant with CE standa...

Page 14: ... Fine Green Green Green 5 Auto strobe BlueGreen BlueGreen BlueGreen 6 Auto Blue Blue Blue 7 RoyalBlue RoyalBlue RoyalBlue 8 Amber Amber Amber 9 Strobe Strobe 10 Macro Macro 11 Auto Auto 12 Color Temperature Value Function Ch05 Ch06 Ch08 Ch11 Ch12 Intensity 0 255 Intensity 0 to 100 Saturation 0 255 Saturation 0 to 100 Hue 0 255 Hue 0 to 100 Hue Fine 0 255 Hue Fine 0 to 100 3 3 1 Mode Channel 1 1 1 ...

Page 15: ...ngeRed 0 255 OrangeRed 0 Black 255 100 Red Green 0 255 Green 0 Black 255 100 Red BlueGreen 0 255 BlueGreen 0 Black 255 100 Red Blue 0 255 Blue 0 Black 255 100 Red RoyalBlue 0 255 RoyalBlue 0 Black 255 100 Red Amber 0 255 Amber 0 Black 255 100 Red Macro 0 1 no function 2 255 127 Macros Auto 0 9 no function 8 8 6 6 4 4 4 5 5 5 10 10 11 11 3 3 3 2 2 2 8 6 7 7 7 4 5 9 9 5 6 14 ...

Page 16: ...oyalBlue Amber Turning On Off in Sequence 100 109 Red OrangeRed Green BlueGreen Blue RoyalBlue Amber Turning On Off in Sequence 110 119 Red OrangeRed Green BlueGreen Blue RoyalBlue Amber Rolling in Sequence 120 129 2 mixup of 7 colors rolling 130 139 3 mixup of 7 colors rolling 140 149 4 mixup of 7 colors rolling 150 255 3 mixup of 7 colors exchange rolling Color Temperature 0 9 Normal 6500K 10 19...

Page 17: ...hen the temperature is greater than 60 degrees the fan runs in full speed 1 Restore factory settings will clear all settings parameter value restore to factory defaults 2 Operation instructions keep pressing up and down keys until the Init interface appears Under the Init interface press the OK button to clear all the parameters and restore the factory defaults Any of the other three keys will exi...

Page 18: ...5 degree fogging surface diameter 19 6mm height 19 6mm 200711000015 2 Aluminum alloy base 330711100006 3 Main control panel 330711100014 4 350W power supply 330000300005 5 Cooling fan DC plastic blade propeller fan AD0812MB C70 159901101229 6 Display 330711100007 7 XLR signal panel 330386100002 8 Adapter plate 339907033502 ...

Page 19: ...Fixed plate for lens 13 Display 4 Lens 14 XLR signal panel 5 Aluminum alloy base 15 Main control panel 6 Left and right end cover 16 The silicone thermal pad 7 Aluminum alloy profile 17 Fixed plate for main control panel 8 Fixed plate for power 18 Left and right side panels 9 350W power supply 19 Lamp bracket 10 Cooling fan 20 Curved plastic pumps ...

Page 20: ...206 92 52 268 67 30 191 48 21 95 66 15 10 10 7 4 3 24 17 33 23 17 11 7 12 8 5 3 05 6 09 9 14 12 19 15 14 2 96 5 92 8 88 11 84 14 80 3 20 6 39 9 59 12 78 15 98 3 10 6 20 9 30 12 41 15 51 3 14 6 28 9 42 12 55 15 69 3 07 6 13 9 20 12 26 15 33 3 08 6 17 9 25 12 33 15 42 3 12 6 24 9 36 12 48 15 60 18 28 17 76 19 18 18 61 18 33 18 39 18 50 18 72 Horizontal Spot dia m Spot dia m Spot dia m Spot dia m Spo...

Page 21: ...02 2 46 4 91 7 37 9 83 2 33 4 67 7 00 9 34 2 48 4 96 7 44 9 92 2 32 4 65 6 97 9 30 2 31 4 63 6 94 9 25 2 31 4 63 6 94 9 25 11 36 13 64 12 52 15 02 12 28 14 74 11 67 14 01 12 40 14 88 11 62 13 94 11 57 13 88 11 57 13 88 2m 4m 6m 8m 10m 12m 14m 14m 12m 10m 8m 6m 4m 2m 0m Spot dia m Spot dia m Spot dia m Spot dia m Spot dia m Spot dia m Spot dia m Spot dia m Spot dia m Vertical W lux RylB lux B lux B...

Reviews: