1.  Product Identification - Labels and Symbols

“Before installing the VSN300 Wifi Logger Card it is strongly recommended to previously read both the present Quick Installation Guide (QIG) and the 

product manual (available on FIMER official web site www.fimer.com).

The present QIG refers to VSN300 Wifi Logger Card in FW version 1.8.x on.

The VSN300 WIFI LOGGER CARD printed circuit board will be marked with the following information, identifying the product:

-Manufacturer Mark/Trade Mark

-CE (European Union) Marking

-RCM (Australia) Marking 

-FCC ID

The FCC ID is FCC ID: X6W-3N16E when the VSN300 WIFI LOGGER CARD is assembled with a Wi-Fi radio module supplied by Epcos

The FCC ID is FCC ID: X6W-3N16M when the VSN300 WIFI LOGGER CARD is assembled with a Wi-Fi radio module supplied by Murata

A dedicated label including the FCC ID must be placed in a visible position on the exterior of the Inverter host equipment 

Contains FCC ID: X6W-3N16E

Contains FCC ID: X6W-3N16M

FCC (Federal Communications Commission) WARNING

1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may 

cause undesired operation

2. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These 

limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses 

and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to 

radio communications.  However, there is no guarantee that interference will not occur in any particular installation.  If this equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to 

correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

3. RF Exposure. This device complies with Part 2.1091 of the FCC Rules for an uncontrolled environment. This equipment should be installed and 

operated with a minimum distance of 20cm between the antenna and the user.

Refer to the specific section describing procedures how to integrate and use this device into the host fixed mount inverter.

Changes or modifications made to this equipment not expressly approved by the Manufacturer may void the FCC authorization to operate this equipment.

The identification label contained on the VSN300 WIFI LOGGER CARD box has information regarding the device and manufacturer.

FIMER
VSN300 WIFI LOGGER CARD

SN: YYWWSSSSSS

MAC:  XX:XX:XX:XX:XX:XX

PRODUCT KEY:  XXXX - XXXX - XXXX - XXXX

- Manufacturer name

- Model name

- Serial Number composed of:

YY = Year of production

WW = Week of production

SSSSSS = progressive number

- VSN300 WIFI LOGGER CARD Mac address

- Product Key composed of 16 characters used to activate the VSN300 WIFI LOGGER CARD

In some cases on the equipment, dangerous or hazardous zones are indicated with signs, labels, symbols or icons.

In the manual and/or in some cases on the equipment, the danger or hazard zones are indicated with signs, labels, symbols or icons.

Always refer to instruction 

manual

Hot surfaces

General warning - Important safety 

information

,3;;

Protection rating of 

equipment

Dangerous voltage

Temperature range

Obligation to use protective clothing 

and/or personal protective equipment

;;

The discharge time of the 

stored energy

2.  Operating diagram

The VSN300 WIFI LOGGER CARD allows for connection of the inverter to a local LAN Wi-Fi network via a wireless connection. 

The VSN300 WIFI LOGGER CARD features an integrated web server that enables establishment of a direct connection to a PC,smartphone or tablet, 

allowing for board configurations and local monitoring of the inverter.

When the inverter is connected to the WLAN network with Internet access, the VSN300 WIFI LOGGER CARD allows for transfer of data to the Aurora 

Vision® Plant Management Platform for remote monitoring purposes over an Internet browser or Mobile App (Plant Viewer for Mobile)

APPLICATION WITH VSN300 WIFI LOGGER CARD

WI-FI router 

INTERNET

POWER     

  ALARM    

     GFI        

          ESC

          UP 

         DOW

N        EN

TER

TRIO

TRIO

POWER       AL

ARM      

   GFI             

     ESC     

     UP

          DOWN        

ENTER

Aurora Vision   

Plant Management Platform™

®

Aurora Vision 

Plant Viewer for Mobile

J1

U8

U3

U11

U7

J2

1

2

23

24

VSN300

WIFI LOGGER CARD 

 ATTENTION – 

A

In order to assure the correct operation of the card do not install other monitoring devices in addition to the VSN300 WIFI LOGGER CARD.

Summary of Contents for VSN300

Page 1: ...uide the safety and installation information provided in the product manual must be read and followed The technical documentation for the product is available at the website The device must be used in the manner described in the manual If this is not the case the safety devices guaranteed by the inverter might be ineffective ...

Page 2: ... help 3 RF Exposure This device complies with Part 2 1091 of the FCC Rules for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the antenna and the user Refer to the specific section describing procedures how to integrate and use this device into the host fixed mount inverter Changes or modifications made to this equipment not expr...

Page 3: ...OGGER CARD and router can be increased in different ways 1 Change the direction of the antenna 2 Find a new location for the router taking care about the signal decrease due to materials through which the radio signal has to pass Before mounting the system it is important to consider the possible scenarios see below and evaluate the right position for Wi Fi router 1 2 NO OK Distance less less than...

Page 4: ...rvice cable glands of the inverter using a 25mm wrench Pass the antenna connection cable into the inverter by passing it through the M20 cable gland opening the gasket the plastic lock nut and the adapter If used Attach the antenna bulk head connector to the inverter using the supplied plastic lock nut torque 5N m For some inverter models UNO 2 0 2 5 I OUTD and TRIO 5 8 7 5 8 5 TL OUTD it will be ...

Page 5: ...U11 U7 J2 1 2 23 24 J1 U8 U3 U11 U7 J2 1 2 23 24 2 3 U7 J2 U7 J2 2 3 Special note for installation on inverter equipped with arc fault device In these type of inverter is necessary to install a standoff supplied with the equipment under the mechanical mounting bracket J1 U8 U3 U11 U7 J2 1 2 23 24 J1 U8 U3 U11 U7 J2 1 2 23 24 Installation with arc fault connection board At the end of installation p...

Page 6: ...t browser 4 Insert all the information required by the configuration wizard 4a Select the language 4a 4b Verify that the time zone of the installation site is correct or insert if it is missing 4b 4c The VSN300 is able to operate in two different modes of operation AP mode access point in this mode is enabled local monitoring only The card behaves like an access point generating a wireless network...

Page 7: ...Plant Portfolio Manager Plant Viewer Plant Viewer for mobile Data Logging Specifications Data sampling rate High frequency data sampling less than 1 minute average Local data storage Log data for 30 days based on 15 minute intervals Upgradeability Remotely via Aurora Vision Plant Management Platform locally via integrated Web User Interface 1 Advanced functionalities Remote O M operations Inverter...

Page 8: ...purchase orders the agreed particulars shall prevail FIMER does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior ...

Reviews: