EN
46
refer to the Local Area Network standard IEEE802.3
NOTE –
D
No initial setup is required to start data transmission
to Aurora Vision.
NOTE –
D
Internet connection is required to use all the Aurora
Vision remote functionalities.
NOTE –
D
Please refer to Aurora Vision documents available
on FIMER website for further information how to get an
Aurora Vision account for remotely monitoring and managing
the installed solar assets.
5.6.1.3 Ethernet cable/s connection procedure:
• Remove the Signals connection box
(08)
by unscrewing the 4
retain screws.
ATTENTION –
A
If any cable is installed on the other cable
gland remember to unscrew it in order to slide the cables
freely.
• Take the Signals connection box
(08)
, unscrew and remove the
Ethernet 1/2 cable gland
(21)
ring and the protective cap.
• Insert the cable/s through the Ethernet 1/2 cable gland
(21)
ring.
• Take one of the three-holes gasket (suitable for the type of cable
used) from the supplied component bag.
• Route the ethernet cable through a three-holes gasket opening
and reinstall it inside the cable gland. Install suitable plastic plug/s
(supplied) in any unused hole of the gasket.
Click
Click
• Reinstall the cable gland ring without firmly tighten it.
• Connect the cable/s on the ethernet connector/s
(11)
.
Click
Click
• Install the signals connection box
(08)
by screwing the 4 locking
screws present on it (see paragraph “3.5.2 Tightening torques”).
• Firmly tighten the Ethernet 1/2 cable gland
(21)
ring (see
paragraph “3.5.2 Tightening torques”).
ATTENTION –
A
If any cable is installed on the other cable
gland remember to screw it.