Tank Care & Maintenance

 

Warning: 

Do not use the tank as a container for fuel oils, kerosene, gasoline or any other petroleum distillate product. All polyole-

fins are softened and permeated by such products. In an enclosed area the vaporization of these materials from the outside sur-
face of the tank could create a dangerous condition.

 

 

The tank should not be used as a pressure vessel nor used with chemicals or solutions having a weight of more than 12 pounds per 
gallon.

 

Store the tank in a dry dark place when not in use. Storage out of sunlight will prolong the life of the tank.

 

Do not drop, strike or kick the tank, especially at low temperatures. Tanks become brittle and are subject to cracking at tempera-
tures below 20° Fahrenheit.

 

 

Always flush the tank with water and a neutralizing agent at the end of each use, to prevent  contamination of solutions.

 

 

Winter Storage

 

Prepare the sprayer for end

-

of

-

season storage by running RV antifreeze through the system. This will keep internal parts lubricat-

ed, protect against corrosion and keep the unit from freezing. 

Note: RV antifreeze is non

-

toxic and biodegradable and generally 

safer for the environment than automotive antifreeze.

 

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough 
pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing 
system, including the bypass. Make sure to operate the handgun until you see pink fluid spraying from the nozzle. Leave any re-
maining antifreeze in the tank. Before your next usage, rinse the antifreeze from the sprayer with clean water.

 

 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage 
parts of the sprayer. Pumping the antifreeze through the system will displace the water and help prevent this damage.

 

 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and 
flush water properly.

 

DO

 

• 

Clean and rinse your pump after each use with Fimco Tank      
Neutralizer.

 

• 

Winterize your pump or sprayer by rinsing, draining and  running 
RV Antifreeze through it before storing for the winter.

 

• 

Use clean water for your spray mixture.

 

• 

Store inside a building when not in use.

 

DON

T

 

• 

Use to pump bleach.

 

• 

Use to pump petroleum products such as diesel fuel, gasoline or 
kerosene.

 

• 

Use to pump chemicals w/petroleum distillates or surfactants.

 

• 

Leave your pump sit with spray mixture in it for extended    
periods.

 

• 

Use dirty or unfiltered water for spraying.

 

Pump Model:  5281370

 

1.2 GPM 

-

 60 PSI

 

Available Replacement Parts

 

Replacement Pump:  5151086

 

Summary of Contents for LG-5-P

Page 1: ...one To obtain prompt efficient service always remember to give the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s of this manual General Information Thank you for purchasing this product The purpose of this manual is to assist you in operating and maintaining yo...

Page 2: ...ss of control or overturn sprayer and vehicle Always operate up and down a slope never across the face of a slope Keep all movement on slopes slow and gradual Do not make sudden changes in speed directions or turning Do not start or stop suddenly when going uphill or downhill Stop on level ground set the parking brake and shut off engine before leaving the operator s position for any reason Keep a...

Page 3: ...lever on the handgun to spray NOTE Pump is equipped with a pressure switch that is pre set at the factory to shut the pump off when all discharges are closed The pump will turn back on when the handgun is activated by squeezing the handle lever Rotating the adjustable nozzle tip on the handgun will change the tip pattern from a straight stream to a cone pattern fine mist Maintenance During After S...

Page 4: ...oroughly clean and drain it as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system including the bypass Make sure to operate the handgun until you see pink fluid spraying from the nozzle Leave any re maining antifreeze in the tank Before your next usage rinse the antifreeze from the ...

Page 5: ...ed to a fully charged battery but the motor won t run then it s time to check to see if the pressure switch is bad Remove the cover off the 1 square box pressure switch on the head of the pump the cover is held on by one phillips head screw This will expose the two red wires With the pump connected to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch ...

Page 6: ...Page 6 Exploded View Parts List LG 5 P 5302165 ...

Page 7: ...Page 7 Approx Dimensions 21 260 17 323 30 510 31 063 18 495 29 500 Back Of Unit See Previous Page for Part Numbers Internal Components See Previous Page for Part Numbers ...

Page 8: ...E To obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco or an authorized dealer within a reasonable period...

Reviews: