background image

Page 3 

 

Operation 

The pumping system draws solution from the tank, through the strainer 
and to the pump. The pump forces the solution under pressure to the 
handgun. 
Connect the lead wire to a fully charged 12 volt battery. You may use 
either a stand-alone battery or the battery on your towing vehicle. The 
lead wire has an On/Off switch to activate the pump. “-” is on and “O” is 
off. 
Fill the tank part way with water and then add the desired amount of 
chemical to be sprayed. Finish filling tank to proper level. Turn the 
pump on and by depressing the “-” side of the rocker switch. The pump 
is equipped with a pressure switch that is pre-set at the factory to shut 
the pump off when all discharges are closed. 
The pump will turn back on when the handgun lever is squeezed to 
spray. 

 

Activate the handgun by squeezing the handle lever 

 

Rotating the adjustable nozzle tip on the handgun will change the 
tip pattern from a straight stream to a cone pattern (fine mist) 

 

WARNING: 

Some chemicals will damage the pump valves if 

allowed to soak untreated for a length of time! ALWAYS  flush the 
pump as instructed after each  use. DO NOT allow chemicals to sit 
in the pump for extended times of idleness. Follow the chemical 
manufacturer’s instructions on disposal of all waste water from 
the sprayer. 

Maintenance During/After Spraying 

Periodically check and clean the strainer on your intake tube. 
Proper care and maintenance will prolong the life of your sprayer. 
 
After use, fill the sprayer half way with clean water. Start the pump 
and allow the water to pump through the entire plumbing system and 
handgun nozzle. Drain and then refill half full, add the recommended 
amount of a good quality tank cleaner, such as FIMCO Tank 
Neutralizer and Cleaner. (If no tank cleaner is available, you may 
substitute dish soap for this step).  Turn pump on and circulate 
through system for 15 minutes and then spray out through the 
handgun nozzle. Refill sprayer half way with clean water and repeat. 
Follow the chemical manufacturer’s disposal instructions of all wash 
or rinsing water. If handgun nozzle needs cleaning, remove nozzle 
and soak in warm soapy water. Clean with a soft bristled brush if 
necessary. 

Winter Storage 

Before storing your sprayer for winter or long term storage, 
thoroughly clean and drain it as much as possible. Then pour enough 
pink RV antifreeze into the tank so that when the pump is turned on 
you can pump the antifreeze throughout the entire plumbing system. 
Make sure to operate the handgun until you see pink fluid spraying 
from the nozzle. Leave any remaining antifreeze in the tank. Before 
your next usage, rinse the antifreeze from the sprayer with clean 
water. 
It is nearly impossible to drain all of the water from the sprayer and 
any trapped water can freeze in cold weather and damage parts of 
the sprayer. Pumping the antifreeze through the system will displace 
the water and help prevent this damage. 

Exploded View/

Parts List 

LG-40-DLX 

(5302186) 

Reviews: