Fimco 5303070 Owner'S Manual Download Page 5

Page 5 

 

Manifold Valves CLOSED 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of 

any foreign material. Rinse tank out of any tank residue before filling with 

water to test.

 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual 

spraying is attempted. This will enable you to check the sprayer for leaks without 

the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the 

boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The 

pump forces the solution under pressure to the handgun or boom nozzles. 

 

NOTE:

 Read and follow the Volt Edge instructions, later in this manual, for charging and  

operation of the 20Vmax Lithium Ion System. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. 

Finish filling tank to proper level. Turn the pump on and by depressing the “-” side of the rock-

er switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut 

the pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly 

opening the bypass valve until desired pressure is achieved. Opening the valve decreases 

pressure, closing the valve increases pressure. When spraying with the boom, the proper 

method to set the pressure is to open the boom valve completely and if a lower pressure is 

desired, then slowly open the bypass valve until that pressure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer 

using the tip and speed charts. Once you have determined the proper speed and pressure settings, you will need to consult your chemical label for the 

amount of chemical to be added to the tank. Read the entire label. Use only according to label directions. 

 

Calibration 

Chemical labels may show application rates in gallons per acre, gallons per 1000 square feet or gallons per 100 square feet. You will note that the tip 

chart shows 3 of these rating systems. Once you know how much you are going to spray, then determine (from the tip chart) the spraying pressure 

(PSI), and the spraying speed (MPH). 

 

Determining the proper speed of the pulling vehicle can be done by marking off 100, 200 & 300 feet. The speed chart indicates the number of seconds 

it takes to travel the distances. Set the throttle and with a running start, travel the distances. Adjust the throttle until you travel the distances in the 

number of seconds indicated by the speed chart. Once you have reached the throttle setting needed, mark the throttle location so you can stop and go 

again, returning to the same speed. 

 

Add water and proper amount of chemical to the tank and drive to the starting place for spraying. 

Detail A 

Detail B 

Summary of Contents for 5303070

Page 1: ...ting instructions for both the sprayer and the Volt Edge system before using IMPORTANT This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM C...

Page 2: ...ur sprayer s carton 20V 30 2N TRL Tank Plumbing Pre Assembly Owner s Manual Breakaway Boom Bracket Kit LG 30 TRL 5278366 Tongue Assembly Wireless Remote 5164291 20V 1A Lithium Battery Charger 5164281 Contents of Parts Bag 5281516 ...

Page 3: ...6 x 2 1 4 Flanged bolts tank support axle support and the preassembled tongue Turn the tank upside down Detail A Loosely attach the tank support and axle support with 4 lock screws Just start the bolts do not tighten on either support Detail B Slide the tongue assembly into place and using the 2 flanged bolts attach to the tank and tighten Do Not Overtighten Then tighten the 4 lock screws Do Not O...

Page 4: ...ank using the two screws DO NOT TIGHTEN Detail C Locate in the parts bag 2 5 16 18 x 5 8 Flanged Bolts and 2 Whiz Nuts Attach the Boom Top Straps to the Boom Assembly using the two bolts and whiz nuts Tighten all Bolts from Details A B C DO NOT OVERTIGHTEN After the boom is installed attach the 8 Feeder Hose to the 90 HB Elbow on the manifold The boom is now installed Locate the Pressure Gauge in ...

Page 5: ...d then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that is pre set at the factory to shut the pump off when all discharges are closed The pump will turn back on when one of the following actions occurs Handgun lever is squeezed to spray the handgun ...

Page 6: ...tructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep internal parts lubricated protect against corrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before storing your s...

Page 7: ...ischarge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adjusted for a small or fine spray pattern Slightly open bypass if applicable to overcome If needed pressure switch may need to be adjusted adjust a quarter ...

Page 8: ...o see if the pressure switch is bad Remove the cover off the 1 square box pressure switch on the head of the pump the cover is held on by one phillips head screw This will expose the two red wires With the pump connected to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs t...

Page 9: ...reduce the risk of injury basic safety precautions should always be followed including Charge battery packs only in Volt Edge 20V max Lithium ion compatible chargers Do not store or charge the battery pack in locations where the temperature may reach above 95 F 35 C or below 40 F 4 C Do not use the battery pack in locations where the temperature may reach above 120 F 49 C or below 4 F 20 C Warning...

Page 10: ...y Chargers DOE energy conser vation standards specified in the Code of Federal Regulations at 10 CFR 430 32 z This device complies with CEC Section 1605 1 w of energy efficiency standars for federally regulated battery chargers of California Code of Regulations This device complies with NRCAN EEV CSA C381 2 17 May 2017 and Canada s Energy Efficiency Regulations This device complies with cETLus cer...

Page 11: ...d it is fully seated 4 Press the power button and confirm the green LED turns on Signaling the power is on 5 Test the remote by pressing the OFF button on the remote and both green and red receiver LEDs will turn on Signaling the power output is off while the power is on 6 Press the ON button on the remote The red LED will turn off and power output will return 7 Press the power button again to tur...

Page 12: ...f this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differe...

Page 13: ...Page 13 Exploded View Parts List 20V 30 2N TRL 5303070 See Intake Assembly Detail Page 15 See Manifold Assembly Detail Page 15 See Boom Assembly Parts List Next Page ...

Page 14: ...gested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift Hinge Detail ...

Page 15: ...s with an On Off shut off valve located at the inlet location of the tank towards the underside You must make sure the valve is in the open position before using your sprayer See Page 13 for Part Numbers Manifold Detail Intake Detail ...

Page 16: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: