Using the Boom Nozzles 

Four things must be considered before spraying with the boom. 

 

How much chemical must be mixed in the tank. 

 

Rate of spray (gallons per acre to be sprayed). 

 

What pressure (p.s.i.) will be used. 

 

Speed traveled (mph) while spraying. 

 

Refer to the chemical label to determine your chemical 
mixture 

 

See the tip chart to determine the pressure to be used. The chart will also show the 
speed used when spraying. 

 

Start the pump and open the valve to the boom nozzles. 

 

Check the spray pattern. Usually you can see the coverage better on a solid concrete 
surface, such as a driveway. 

 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line. 

Proper care and maintenance will prolong the life of your sprayer. 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half way 

with clean water. Start the pump and allow the water to pump through the entire plumbing 

system and nozzles. Drain and then refill half full, add the recommended amount of a good 

quality tank cleaner, such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is 

available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  Turn pump 

on and circulate through system for 15 minutes and then spray out through boom and hand-

gun nozzles. Refill sprayer half way with clean water and repeat. Follow the chemical manu-

facturer’s disposal instructions of all wash or rinsing water.  

If boom or handgun nozzles need cleaning, remove them from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick 

if necessary. Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tips before 

storing. 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS flush the pump as 

instructed after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s 

instructions on disposal of all waste water from the sprayer.

 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV antifreeze through the system. This will keep internal parts lubricated, protect against 

corrosion and keep the unit from freezing. 

Note: RV antifreeze is non-toxic and biodegradable and generally safer for the environment than automotive 

antifreeze.

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough pink RV antifreeze 

into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system, including the bypass. Make sure 

to operate the boom and handgun until you see pink fluid spraying from the nozzles. Leave any remaining antifreeze in the tank. Before your next 

usage, rinse the antifreeze from the sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage parts of the sprayer. 

Pumping the antifreeze through the system will displace the water and help prevent this damage. 

 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and flush water properly. 

There is a shut-off valve on the intake line. It is at this location so you can shut 

off the flow of solution to access your system’s filter screen for cleaning. 

 

Checking/Cleaning the sprayer’s filter/screen: 

 

Start your pump and before it shuts off, reach down and shut the valve to 
the ‘Closed’ position (lever is perpendicular to the flow of fluid), then shut 

off your pump. 

 

Unscrew the bowl of the filter to access the screen. 

 

Remove the screen and clean as necessary. Replace when done and    
reassemble the entire assembly. 

 

Make sure the valve is turned to the ‘Open’ position before restarting your 
pump. 

Speed Chart 

  

Time Required in seconds 

to travel a distance of 

Speed in M.P.H. 
(Miles Per Hour) 

100 Ft. 

200 Ft. 

300 Ft. 

1.0 

68 sec. 

136 sec.  

205 sec. 

2.0 

34 

68 

102 

3.0 

23 

45 

68 

4.0 

17 

34 

51 

5.0 

14 

27 

41 

6.0 

11 

23 

34 

7.0 

9.7 

19 

29 

8.0 

8.5 

17 

26 

9.0 

7.6 

15 

23 

10.0 

6.8 

14 

20 

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

6

MPH

8

MPH

10

MPH

15

.12

35.6

17.8

11.8

8.9

7.1

5.9

4.5

3.6

20

.14

41.6

20.8

13.8

10.4

8.3

6.9

5.2

4.2

30

.17

50.4

25.2

16.8

12.6

10.1

8.4

6.3

5.0

40

.20

59.6

29.8

19.8

14.9

11.9

9.9

7.4

5.9

1

MPH

2

MPH

3

MPH

4

MPH

5

MPH

6

MPH

8

MPH

8

MPH

15

.12

.41

.27

.20

.16

20

.14

.48

.32

.24

.19

30

.17

.58

.39

.29

.23

40

.20

.68

.45

.34

.27

AIXR11002VP

AIXR11002VP

Tip

No.

Pressure

(psi)

Capacity

(GPM)

Gallons Per 1000 Sq. Ft. - Based on Water

Spray Tip Rate Chart (20" Spacing)

Tip

No.

Pressure

(psi)

Capacity

(GPM)

Gallons Per Acre - Based on Water

Summary of Contents for 5302830

Page 1: ...within it s load carrying capacity Secure unit in your UTV using tie down straps NOT INCLUDED IMPORTANT REMINDER This sprayer comes with an On Off valve located on your intake line You must make sure the valve is in the open position before using your sprayer OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should ha...

Page 2: ...om hose Slip 2 3 8 hose clamps onto hose Attach one end of hose to the boom and the other end to the manifold The boom hose can be cut to length if needed Once fully assembled to remove the sprayer from a UTV Box disconnect the boom supply hose from the manifold using the quick connect fitting Then loosen the two lobe knobs on the tank mounts and slide the boom out and set aside Then the tank can ...

Page 3: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Page 4: ...rosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze Before storing your sprayer for winter or long term storage thoroughly clean and drain it as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire...

Page 5: ...e assembly Check for defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may ...

Page 6: ...move the head of the pump which is held on by 7 screws The first piece inside the head of the pump is called a check valve it s the part responsible for building up pressure and pumping water solution through the lines Clean the check valve under hot soapy water such as a good grade dish soap Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wirin...

Page 7: ...e 7 Exploded View UTV 65 7 5302830 Refer to Parts List Next Page for Part Numbers Detail B Detail A See Detail A Refer to Page 10 for the UTV intake assembly breakdown Reference 6 Detail B Boom Feeder Hose ...

Page 8: ...Page 8 Parts List UTV 65 7 5302830 Manifold Detail 5281540 Boom Tube Assembly Detail Boom Mount 5278715 Strainer 5116417 ...

Page 9: ... spacing Suggested Minimum Spray Height 16 18 above what is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction tech nology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance including acids as well as exceptional wear life Compact size to prevent tip damage Excellent for sy...

Page 10: ...roceed to step 4 4 Open fill cap and place garden hose into tank Add water to the desired gallon marker Close fill cap pressing firmly to seal cap to Multi Lid NOTE If water and chemical has not mixed properly use the pressure adjustment control on the manifold to recirculate the mixture through tank 34 16 47 34 36 Technical Specifications Properly secure the tank to your utility vehicle using tie...

Page 11: ...Page 11 NOTES ...

Page 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: