background image

Page 3 

 

Step 6: 

 

Place a hose clamp over the end of the feeder hose loosely. Slip the end of the hose over 

the hose barb on the center nozzle. Use a twisting motion, if necessary, to get the hose fully 

onto the barb. Bring the hose clamp to the connection point and tighten securely. 

End Nozzle Information 

This nozzle mounting stem 

Has a ratcheting motion. 

** Each “click” of the ratcheting motion is approx. 15° ** 

For proper/optimal spray coverage, 

The nozzle must be at a 15° angle 

 

The 15° angle shown will prevent the outer 

Nozzles from overlapping with the center nozzle. 

“On/Off” Valve Positions 

Valve “Open” 

Valve “Closed” 

Service Position 

On/Off Valve Knob 

Eliminate line pressure, then pull out 

to check diaphragm condition. 

Note: The check valve & diaphragm can fall out during transport, if the 

knob is not turned to the “ON” or “OFF” position. 

15° 

Summary of Contents for 5301305

Page 1: ...45 lbs Consult the owner s manual for your vehicle to verify that you are within it s load carrying capacity OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above O...

Page 2: ...TIGHTEN the whiz lock nuts as this may cause the boom tube to flatten slightly End Nozzle Assembly Procedure For Boomless Wet Boom Your boom will come with the 2 end nozzle assemblies NOT affixed to your boom tube Follow the instructions below to attach these properly to the boom tube as shown Assembled End Nozzle 1 Start by sliding Item 4 3 2 onto the boom tube Item 1 as shown leaving about 1 2 t...

Page 3: ...e mounting stem Has a ratcheting motion Each click of the ratcheting motion is approx 15 For proper optimal spray coverage The nozzle must be at a 15 angle The 15 angle shown will prevent the outer Nozzles from overlapping with the center nozzle On Off Valve Positions Valve Open Valve Closed Service Position On Off Valve Knob Eliminate line pressure then pull out to check diaphragm condition Note ...

Page 4: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Page 5: ...ic and biodegradable and generally safer for the environment than automotive antifreeze Before storing your sprayer for winter or long term storage thoroughly clean and drain it as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system including the bypass Make sure to operate the boom ...

Page 6: ...r defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge...

Page 7: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Page 8: ...Page 8 Exploded View Parts List ATVTS 60 12V BL 5301305 Axle Attachment See Next Page Hub Detail See Next Page Boom Assembly See Next Page Pump Manifold Assemblies See Next Page ...

Page 9: ...mbly Boom Attachment Axle Attachment Hub Detail 5302350 Manifold Assembly Boomless Wet Boom Assembly Exploded View Parts List 5275260 5116417 Strainer Assembly Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122 Refer to Parts List Previous Page for Part Numbers ...

Page 10: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: