background image

Page 2 

 

Manifold Valves CLOSED 

Detail A 

Detail B 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of any foreign 

material. Rinse tank out of any tank residue before filling with water to test. 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual spraying is 

attempted. This will enable you to check the sprayer for leaks without the possibility of losing 

any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, close both valves on manifold (Detail A). This will start solution spraying 

from the spraygun when trigger is pulled. The pressure will decrease slightly when spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). Make sure 

your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solution back into the tank. 

This is achieved by opening the bypass valve. Regulating pressure is done in this manner. 

 

Read the operating instructions and initially begin spraying by closing both  valves (Detail A). This will 

enable the air in the line to be eliminated (purged) through the tip, while building pressure. When every-

thing tests all right (no leaks and good pressure), add the desired chemicals to the mixture and water 

combination and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray on windy 

days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The pump  

forces the solution under pressure to the handgun. 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone battery or the battery on your towing vehicle. Connect to the 

positive (red) terminal first, then connect to the negative (black) terminal. Then connect the end of the lead wire to the end of the pump. When discon-

necting, disconnect the end of the pump wire from the lead wire, then disconnect the negative (black) connection and finally the positive (red) connec-

tion. The lead wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. Finish filling tank to proper level. Turn the pump on and 

by depressing the “-” side of the rocker switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut the pump off when all 

discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun.   

♦     Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with the handgun, pressure may be reduced by slowly opening the bypass valve until desired pressure is achieved. Opening the valve 

decreases pressure, closing the valve increases pressure. 

 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line.  

 

Proper care and maintenance will prolong the life of your sprayer. 

 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half 

way with clean water. Start the pump and allow the water to pump through the entire 

plumbing system and nozzle. Drain and then refill half full, add the recommended 

amount of a good quality tank cleaner, such as FIMCO Tank Neutralizer and Cleaner. 

(If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  Turn pump on and circulate through system for 15 

minutes and then spray out through handgun nozzle. Refill sprayer half way with clean water and repeat. Follow the chemical manufacturer’s disposal 

instructions of all wash or rinsing water. 

  

If handgun nozzle needs cleaning, remove from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick if necessary. 

Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tip before storing. 

 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS 

flush the pump as instructed 

after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s instructions on disposal 

of all waste water from the sprayer. 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV antifreeze through the system. This will keep internal parts lubricated, protect against 

corrosion and keep the unit from freezing. 

Note: RV antifreeze is non-toxic and biodegradable and generally safer for the environment than automotive 

antifreeze.

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough pink RV antifreeze 

into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system, including the pressure adjust 

(bypass) line. Make sure to operate the boom and handgun until you see pink fluid spraying from the nozzles. Leave any remaining antifreeze in the 

tank. Before your next usage, rinse the antifreeze from the sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage parts of the sprayer. 

Pumping the antifreeze through the system will displace the water and help prevent this damage. 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and flush water properly. 

Summary of Contents for 5301304

Page 1: ...u have purchased the optional trailer kit or optional boom assembly BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to he...

Page 2: ...gun Bypass valve is opened to re circulate solution back into the tank When spraying with the handgun pressure may be reduced by slowly opening the bypass valve until desired pressure is achieved Opening the valve decreases pressure closing the valve increases pressure Maintenance During After Spraying Periodically check the strainer and clean the screen on your intake line Proper care and mainten...

Page 3: ...alve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adju...

Page 4: ...ed to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing th...

Page 5: ...Page 5 See Plumbing Detail Next Page Exploded View SK 61 12V 5301304 Refer to Parts List Next Page for Part Numbers Loom Clamp for Handgun Hose ...

Page 6: ...Page 6 Parts List SK 61 12V 5301304 Plumbing Detail Refer to the Parts List Above for Part Numbers Intake Hose Bypass Hose ...

Page 7: ...Page 7 NOTES ...

Page 8: ...ain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable pe...

Reviews: