Fimco 3PT-45-12V-4 Owner'S Manual Download Page 12

Page 12 

 

LIMITED WARRANTY FOR NEW FIMCO, IND. EQUIPMENT 

WHO MAY USE THIS LIMITED WARRANTY.  This limited warranty (the “Limited Warranty”) is provided  by  Fimco, Ind. to the original purchaser 
(“you”) of the Equipment (as defined below) from Fimco, Ind. or one of Fimco, Ind.’s authorized dealers. This Limited Warranty does not apply to 
any subsequent owner or other transferee of the Equipment. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO 
HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.   

 

WHAT THIS LIMITED WARRANTY COVERS AND FOR HOW LONG.  Fimco, Ind. warrants that any new Equipment will be free from defects in  
material and workmanship for a period of 

one (1) year

 for sprayer and 

two (2) years

 for High-Flo High Performance pump (homeowner), 

90 days 

for sprayer and pump (commercial user), after delivery of the Equipment to you (the “Warranty Period”). The Warranty Period is not extended if 
Fimco, Ind. repairs or replaces the Equipment.  

 

WHAT IS NOT COVERED BY THIS LIMITED WARRANTY.  This Limited Warranty does not apply to: (1) used Equipment; (2) any Equipment that has 
been altered, changed, repaired or treated since its delivery to you, other than by Fimco, Ind. or its authorized dealers; (3) damage or deprecia-
tion due to normal wear and tear; (4) defects or damage due to failure to follow Fimco, Ind.’s operator’s manual, specifications or other written 
instructions, or improper storage, operation, maintenance, application or installation of parts; (5) defects or damage due to misuse, accident or 
neglect, “acts of God” or other events beyond Fimco, Ind.’s reasonable control; (6) accessories, attachments, tools or parts  that were not manu-
factured by Fimco, Ind., whether or not sold or operated with the Equipment; or (7) rubber parts, such as tires, hoses and grommets.   

 

HOW TO OBTAIN WARRANTY SERVICE.  To obtain warranty service under this Limited Warranty, you must (1) provide written notice  to Fimco, 
Ind. of the defect during the Warranty Period and within 

thirty (30)

 days after the defect becomes apparent or the repair becomes necessary, at 

the following address: Fimco, Ind., 1000 Fimco Lane, North Sioux City, SD 57049; and (2) make the Equipment available to Fimco, Ind. or an  
authorized dealer within a reasonable period of time. For more information about this Limited Warranty, please call: 

800-831-0027

.

 

 
WHAT REMEDIES ARE AVAILABLE UNDER THIS LIMITED WARRANTY.  If the conditions set forth above are fulfilled and the Equipment or any part 
thereof  is  found  to  be  defective,  Fimco,  Ind.  shall,  at its  own  cost,  and  at  its  option,  either  repair  or  replace  the  defective  Equipment  or  part. 
Fimco, Ind. will pay for shipping and handling fees to return the repaired or replacement Equipment or part to you.   

 

LIMITATION OF  IMPLIED  WARRANTIES  AND  OTHER  REMEDIES.   THE  REMEDIES  DESCRIBED  ABOVE  ARE YOUR  SOLE  AND  EXCLUSIVE REMEDIES, 
AND  FIMCO,  IND.’S  SOLE  LIABILITY,  FOR  ANY  BREACH  OF  THIS  LIMITED  WARRANTY.  TO  THE  EXTENT  APPLICABLE,  ANY  IMPLIED  WARRANTIES, 
INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIM-
ITED  IN  DURATION  TO  THE  WARRANTY  PERIOD,  AND  THE  REMEDIES  AVAILABLE  FOR  BREACH  THEREOF  SHALL  BE  LIMITED  TO  THE  REMEDIES 
AVAILABLE  UNDER  THIS  EXPRESS  LIMITED  WARRANTY.  SOME  STATES  DO  NOT  ALLOW  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY 
LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. IN NO EVENT SHALL FIMCO, IND.’S LIABILITY UNDER THIS LIMITED WARRANTY EX-
CEED THE ACTUAL AMOUNT PAID BY YOU FOR THE DEFECTIVE EQUIPMENT, NOR SHALL FIMCO, IND. BE LIABLE, UNDER ANY CIRCUMSTANCES, 
FOR  ANY  CONSEQUENTIAL,  INCIDENTAL,  SPECIAL  OR  PUNITIVE  DAMAGES  OR  LOSSES,  WHETHER  DIRECT  OR  INDIRECT.  SOME  STATES  DO  NOT 
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT 
APPLY TO YOU.

 

Warranty 

Dimensions 

19.000” 

93.505” 

37.250” 

24.847” 

24.625” 

23.000” 

27.000” 

34.563” 

29.309” 

Summary of Contents for 3PT-45-12V-4

Page 1: ...ervice always remember to give the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s of this manual General Information Thank you for purchasing this product The purpose of this manual is to assist you in operating and maintaining your 3 Point sprayer Retain a copy...

Page 2: ...ortant for you to test your sprayer with plain water before actual spraying is attempted This will enable you to check the sprayer for leaks without the possibility of losing any expensive chemicals WARNING Read and Understand the Owner s Manual completely before using this sprayer Assemble test and use in accord ance to manual instructions Read and Follow chemical label instructions and wear prot...

Page 3: ...Owner s Manual Tank Plumbing Pre Assembly Bolt Together 3 PT Sides 3 PT Back Plate 3 PT Welded Front Frame Boom Mounts 4 Nozzle Boom Assembly Contents of Parts Bag 5282432 Contents of Square Boom Parts Bag 5282433 Contents of Bolt Bag 5282434 ...

Page 4: ...lates slip the lock washers on and thread the nuts onto the pin Tighten securely T h is s id e to w a rd s ta n k Step 2 Bolt the frame together as shown Attach one side plate side plates are the same to the front frame weldment using 3 3 8 16 x 1 Flange Whiz Lock Screws and 3 3 8 16 Hex Whiz Nuts Attach back tie plate to side plate using 3 3 8 16 x 3 4 Flange Whiz Lock Screws and 3 3 8 16 Hex Whi...

Page 5: ...e boom and using the nozzle clamps attach the nozzle harness to the boom Step 6 After your nozzle harness is attached to the boom attach the boom feeder hose Place 2 hose clamps loosely onto each end of the hose loosely Slip the ends of the hose over the hose barbs on both the manifold and the poly tee fitting on the nozzle har ness Use a twisting motion if necessary to get the hose fully onto eac...

Page 6: ...h the strainer and to the pump The pump forces the solution under pressure to the handgun or boom nozzles Connect the lead wire to a fully charged 12 volt battery You may use either a stand alone battery or the battery on your towing vehicle Connect to the positive red terminal first then connect to the negative black terminal Then connect the end of the lead wire to the end of the pump When disco...

Page 7: ...ill sprayer half way with clean water and repeat Follow the chemical manu facturer s disposal instructions of all wash or rinsing water If boom or handgun nozzles need cleaning remove them from the sprayer and soak in warm soapy water Clean with a soft bristled brush or toothpick if necessary Never use a metal object Even the slightest damage can change the flow rate and spray distribution Water r...

Page 8: ...iring Make sure the ON OFF switch is on Check to see if connected to good Check for Low Voltage Troubleshooting Check for a clogged strainer Check for proper voltage Check for leaks in the discharge line Check for restrictions in the discharge line Check for debris in intake Check for debris in nozzle orifice Check for worn or dirty check valve Low Pressure Low Flow Pump Does Not Prime No Discharg...

Page 9: ...mmended to replace this part Sprayer and Pump FAQs Why does the pump not run all the time This is an on demand pump and only runs when a discharge is open spray gun bypass boom if applicable or a leak is in the system Why does the pump surge while using the spray gun Low flow high pressure may cause the pump to surge or cycle Typically the spray wand is adjusted at too fine of a mist to overcome a...

Page 10: ...10 Exploded View Parts List 3PT 45 12V 4 5303244 NOTE Bolt frame together as shown with the proper hardware See Assembly Instructions earlier in this manual Manifold Detail Intake Hose Boom Hose Bypass Hose ...

Page 11: ...t is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction technology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance includ ing acids as well as exceptional wear life Compact size to prevent tip damage Excellent for systemic products and drift management Opposite side has ...

Page 12: ...mited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information ...

Reviews: