PREPARATION OF THE APPLIANCE
2.
House the batteries in the compartment, positioning the poles “+” and “-“ opposite each other
3.
Connect to the battery drop cable (1) to the "+" and "-" terminals, so as to create a 24V voltage at the terminals.
4.
Connect the battery connector (2) to the general system connector (3).
ATTENTION: It is recommended that all installation and maintenance operations should be carried out by expert personnel, trained
by the dedicated technical service centre.
WARNING: you are advised to always wear protective gloves, to avoid the risk of serious injury to your hands.
5.
Grip the handle on the recovery tank and turn until it reaches the work position.
9.
BATTERY CHARGER CONNECTION (only for systems without CB)
In order not to cause permanent damage to individual battery elements, it is essential to avoid their complete discharge by recharging them within a few
minutes from the "discharged battery" warning light being switched on.
ATTENTION: Never leave individual battery elements completely discharged, even if the machine is not in operation. Check the
battery charger is suitable for the batteries installed, in terms of both capacity and type.
To connect the battery charger you must:
1.
Move the appliance to the designated battery charging area.
ATTENTION: Park the device in an area protected from the elements and with suitable ventilation, on a flat and level surface.
There must be no objects near the device that could either damage it, or be damaged through contact with it.
2.
Take all necessary steps to ensure that the device is in a safe condition (see
MACHINE SAFETY
’”).
ATTENTION: this process must be carried out by qualified personnel. An incorrect connection of the connector may cause a
malfunction of the device.
ATTENTION: Check that the battery charger used is suitable for the batteries in the device and set up for the batteries installed.
WARNING: Carefully read the use and maintenance instructions of the battery charger that is used for charging.
3.
Connect the battery charger cable to the battery connector (2).
4.
Connect the recently wired cable to the external battery charger.
WARNING: Keep the recovery tank open for the duration of the battery recharging cycle to allow gas fumes to escape.
WARNING: The room used to recharge the batteries must be adequately ventilated to prevent the accumulation of gases that leak
from batteries.
The coupling connector of the battery charger is supplied inside the bag containing this instruction booklet, and must be fitted to the battery charger
cables as shown in the instructions.
WARNING: Danger of gas exhalation and leakage of corrosive liquids.
WARNING: Danger of fire: do not go near with free flames
5.
When the recharge cycle is complete, disconnect the battery charger supply cable from the battery charger.
6.
Disconnect the battery charger connector from the battery connector (2).
7.
Connect the battery connector (2) to the connector of the general system (3).
8.
Grip the handle on the recovery tank and turn it until it reaches the work position.