ADJUSTMENT
AND
INSPECTION
MINNY 420-430-520
Doc. 10004810
Emesso dic - 06
Rev. 00
Pag.
2 di 6
Adjustment battery check card
1.
Check-up the right set-up of the battery check card. The
adjustment can be performed by
microswitches
.
2.
The possibles configurations are the following:
The right configuration is one of the two above depending on the
battery type.
Inspection of the water supply unit
1.
Fill the solution tank and check the no water leakage condition on
the pipe fitting connections on the
solution cock
and on the
tap
for the drainage
.
2.
Check to have a uniformity in the water spreading on the floor and
that it is easily adjustable regulating the solution cock. In case
check the cleanness of the solution cock.
3.
If the solution cock is obstructed remove the debris from the
opening
A
after the filter has been removed. Clean the solution
tank and leave the water drain from the opening
A
24 V
Pb
24 V
Gel
36 V
Pb
36 V
Gel
A