MONITOR FUNCTION
VIEWING THE LIST OF ALARMS
To perform a preliminary machine diagnosis, proceed as follows:
1. With the machine on, press the menu button (1) on the working screen (
Fig. 1
).
2. Press the setting (2) (
Fig. 2
).
To view the list of alarms that have been active on the machine, proceed as follows:
1. With the machine on, press the menu button (1) on the working screen (
Fig. 1
).
2. Press the setting (2) (
Fig. 2
).
3. In the “MAIN MENU” screen, select the “MONITOR” option (3) on the left-hand side of the screen
(
Fig. 3
).
NB
: when an option is selected from the list, this is highlighted.
4. As soon as the “MONITOR” option is selected, the machine diagnostics screen will appear on the
display (
Fig. 4
).
3. In the “MAIN MENU” screen, select the “MONITOR” option (3) on the left-hand side of the screen
(
Fig. 3
).
NB
: when an option is selected from the list, this is highlighted.
4. As soon as the “ALARMS” option is selected, the machine diagnostics screen will appear on the
display (
Fig. 4
).
5. To return to the work scree, press the “EXIT” key.
5. Select which machine function you want to perform the diagnosis on, choosing one of the options
displayed on the left-hand side of the screen (
Fig. 5
).
NB
: the machine functions are divided as follows:
•
General
•
Brush
•
Pump
•
Vacuum
•
Traction
6. As soon as one of the functions is selected, the information relating to the actuators for this
function appears on the right of the screen (
Fig. 4
).
The table below provides a list of the variables that can be viewed:
7. To return to the program zone menu, press the “BACK” key.
8. To return to the main menu, press the “EXIT” key.
9. To return to the work scree, press the “EXIT” key.
35
OFFICE
0000.00
100%
OFFICE
0000.00
100%
Reset
Menu principale
Lingua
Contaore
Programmazione Zone
Parametri
Monitor
Allarmi
Esci
VISUALIZZATO
TOTALE PARZIALE
Chiave
0000.00 0000.00
Trazione
0000.00 0000.00
Spazzole
0000.00 0000.00
Aspirazione
0000.00 0000.00
Chiave
Reset
Menu principale
Lingua
Contaore
Programmazione Zone
Parametri
Monitor
Allarmi
Esci
VISUALIZZATO
TOTALE PARZIALE
Chiave
0000.00 0000.00
Trazione
0000.00 0000.00
Spazzole
0000.00 0000.00
Aspirazione
0000.00 0000.00
Chiave
ECO mode
0000.00
100%
ECO mode
0000.00
100%
Monitor
General
Brush
Pump
Vacuum
Traction
Esci
Valore 1
100
Valore 2
23.5
Valore 3
Valore 4
A
V
OFF
ON
?
Reset
Menu principale
COUNT
Lingua
Contaore
Programmazione Zone
Parametri
Monitor
Allarmi
Esci
Allarme 1
000
0000.00
Allarme 2
000
0000.00
Allarme 3
000
0000.00
Allarme 4
000
0000.00
HOUR METER
1
1
3
3
2
2
4
4
1
1
3
3
2
2
4
4
UNIT
VARIABLE
U/M
DESCRIPTION
General
Battery voltage
V
Battery voltage
General
Solution empty switch
Solution tank empty float
General
Recovery empty switch
Recovery tank empty float
General
Reverse button
Reverse button
General
Power button
Power button
Brush
Current Brush
A
Brush head brush current
Brush
Actuator Base
Brush head actuator
Brush
Heatsink Temp.
°C
Functions stage temperature
Pump
Flow rate
%
Water flow rate percentage
Pump
ELV base
Brush head solenoid valve
Vacuum
Current
A
Vacuum cleaner current
Vacuum
Voltage
V
Vacuum cleaner voltage
Vacuum
Actuator
Squeegee actuator
Vacuum
Heatsink Temp.
°C
Functions stage temperature
Traction
Voltage
V
Traction motor voltage
Traction
Current
A
Traction motor current
Traction
Overload level
%
Current limit status
Traction
Heatsink Temp.
°C
Traction stage temperature
Traction
Handle POT ref.
V
Gear potentiometer reference voltage
Traction
Handle En.
Dead man's lever pressed