MAINTENANCE OPERATIONS
Unlock of the registers.
Block the pressure stirrup.
13.
CLEANING THE FILTER – CLAMPS AND FILTER SHAKER VERSION
•
Turn the machine off.
•
Remove the debris hopper.
•
Disconnect the red connector of the filter shaker motor
•
Loose the inferior knobs (a).
•
Loosen the superior registers (c) using a coin (b)
•
Lift the clamp and block it turning clockwise the plastic lever (c)
•
Pull out the filter panel (d)
•
Carefully clean the filter using a vacuum cleaner or by manually shaking it.
•
Reassemble by repeating the previous procedures in reverse order.
a
c
b