drum 100 (gravity)
9 LEds for the selected time interval:
Depending on how dirty the water is, you can choose between
5 different flush times.
The normal flush time can be used for average water contami-
nation. If the pond is very clean and hardly contains any
contaminants, such as in the winter time, you can switch to the
"eco" or "smart" setting. This reduces your water consumption. If
the water is heavily contaminated and you would like to flush
the screen more frequently, you can choose the "super" or "turbo"
setting.
You can change the selected flush times in Manual mode by
pressing "Change Flush Time".
The sprayer does not begin spraying until 1.5 seconds after the
motor starts. This ensures that only the soiled portion of the
screen is sprayed.
The Eco setting has a spray time of 5.5 seconds (quarter turn).
The Smart setting has a spray time of 8 seconds (half turn).
The Normal setting has a spray time of 11 seconds (1 turn).
The Super setting has a spray time of 22 seconds (2 turns).
The Turbo setting has a spray time of 33 seconds (3 turns).
Make sure that there is an interval of at least 3 minutes between
flush cycles, otherwise the drum will experience an interval error.
Confirm your choice by pressing "Change Mode". Your choice
is now saved. In manual mode, you can change this again if you
wish.
10 Safety Switch:
If the 'Safety Doorswitch E' is switched on, the system is supplied
with electrical current. After you use 'Safety Doorswitch E', the
system will always start in Manual mode. If you want to open
the control box, you must switch off 'Safety Doorswitch E' or
else the door cannot be opened. This is an additional safety
feature.
10. Cleaning and maintenance
Note! Electrical shock hazard! This can result is severe injury
or death.
When performing cleaning and maintenance, always take the
following measures:
•
Always switch off the power supply and secure it from
being accidentally switched back on before you come into
contact with the water or perform any maintenance work
on the system.
•
General cleaning - 1x each month:
- Switch off the "Main switch" and unplug the system from
the mains power supply.
- Remove any coarse waste (such as algae) on the
inside of the drain.
- Clean the brushes inside the drum.
- Clean the inside of the drum.
- Clean the door security blocks.
- Clean the water level meter electrodes.
•
Cleaning the sprayer heads - 2x per month:
- Remove the sprayer head by turning it to the left
to unscrew it from the quick-release fastener.
- Remove the gasket from the holder.
- Remove the right-angle sprayer from the connector.
- Clean it.
- Install the gasket and sprayer back into the holder.
- Turn the holder onto the clamp bracket.