8
GB
SETTING TORQUE:
1. Remove motor cover.
2. Place torque spanner on M10 nut on the shaft.
3. Prevent drum from turning and torque to 65 Nm.
REPLACING SCREEN PANEL; SEE FIGURE 2/3
Once you have established that the screen panel (M) is showing wear, it is important that you replace it with a new
screen panel (M) as soon as possible. This will ensure the continued optimal performance of the filter.
1. Disconnect the power supply and close the piping.
2. Ensure that the water can drain out of the filter.
3. Turn the drum (L) by hand until the fastening strip (O) and hose clamps (P) are pointing upwards.
4. Now remove the screws (Q) from the fastening strip (O).
5. Loosen the hose clamps (P).
6. Remove the drain channel (N), by unscrewing the two mounting screws (R) at the front.
7. Now remove the screen panel (M) and replace it with a new one.
8. Tighten the hose clamps (P) and fastening strip (O) again. Then check that the assembly is attached correctly.
9. Put the lid back on the housing (F).
10. Now insert the plug in the socket and hold the button (J) for 10 seconds. Now the motor and high pressure
pump are activated again.
When in doubt, always consult a qualified installer.