Fike Twinflex 802-0002 Installation And Maintenance Instructions Download Page 4

 

 

26-0352 Issue 6

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Technical Support 

 

Contact your supplier for technical support on this product. 
 
Due to the complexity and inherent importance of a life risk type system, training on this equipment is essential 
and commissioning should only  be carried  out by competent persons. Fike cannot guarantee the operation of 
any equipment unless all documented instructions are complied with, without variation.  
 
Fike’s policy is one of continual improvement and the right to change a specification at any time without notice is 
reserved. Whilst every care has been taken to ensure that the contents of this document are correct at time of 
publication, Fike shall be under no liability whatsoever in respect of such contents. E&OE. 

 

Summary of Contents for Twinflex 802-0002

Page 1: ...stallation 1st Fix Fix the interface surface boxed single gang in a suitable position remembering to allow enough space for the correct termination of the appropriate cables The interface PCB must be mounted within 15cm of the contacts to be monitored Installation 2nd Fix Once all testing has been carried out on the cabling and continuity integrity of the zone pair has been proven the interface un...

Page 2: ...flex Input Modules Refer to the instruction leaflets supplied with other Twinflex devices for their equivalent wiring terminal labelling details Please note that the screen connections at each Input Module should only be connected to the zone cable screen and NOT to the building earth The cable screen is connected to earth at the panel end only via the zone SCRN terminal or EARTH terminal on the T...

Page 3: ...t Quiescent 834 uA Typical End of line ON if applicable 129 uA Typical in addition to Quiescent Alarm Activated IP Module Detector 20 mA Alarm Activated IP Module Call Point 16 mA Loading Units V3 Panel Pro Panel Max Loading Units per zone 27 SLU 160 DLU IP Module Detector 3 5 SLU 20 0 DLU IP Module Call Point 3 0 SLU 16 0 DLU Flammability UL94 V2 IP Rating IP 21C Part Code Twinflex IP Module Dete...

Page 4: ...competent persons Fike cannot guarantee the operation of any equipment unless all documented instructions are complied with without variation Fike s policy is one of continual improvement and the right to change a specification at any time without notice is reserved Whilst every care has been taken to ensure that the contents of this document are correct at time of publication Fike shall be under ...