background image

Parts Diagram

Compatible Accessories

2

Size IV Barndoor

Powering On

Press the On/Off 
button to turn on the 
light. The button will 
turn green to indicate 
that the light is on.

Locking the Fixture In

Turn the locking knob 
90 degrees to lock the 
fixture in place. Turn 
the channel knob 90 
degrees in either 
direction to select 
desire channel.

Plugging to Power

Ensure correct 
orientation of Data 
Bus on the 
mulit-adapter to the 
Data Bus on the track.

Mounting

Insert the 
multi-adapter into a 
surface track with a 
Data Bus. The locking 
and channel knobs lay 
perpendicular to the 
track.

Adjusting the Settings

Turn the knobs to 
adjust CCT, Hue and 
Intensity.

1. 

Barndoor Brackets

2. 

Yoke Knob

3. 

Barndoor Lock

4. 

Magnetic Accessory Lock 

5. 

Side Vents

6. 

Power Module Box

7. 

5” Fresnel Zoom Lens 

(T365 only)

 

8. 

Lens Tighten Knobs

 

(T365 only)

9. 

Barndoor Brackets 

(T365 only)

10. 

Barndoor Lock 

(T365 only)

11. 

Light Intensity / DMX Address Knob

12. 

Rear Vents

13. 

On / Off Button

14. 

CCT / Hue Tuning Knob

15. 

Yoke

   

16. 

Barndoor Lock Release

17. 

OLED Display 

18. 

Eutrac Multi-Adapter

13

11

14

90º

90º - 0 - 90º

18

DMX Controller

Snoot

Louver

Honeycomb N

Honeycomb W

Dome Diffuser

Fresnel Lens

1

2

3

4

6

7

9

11

12

13

14

15

16

17

18

8

10

Summary of Contents for T360 Series

Page 1: ...User Manual FLXT360 FLXT365 T360 Series 190103A2 ...

Page 2: ... its own integrated Power Module Box 6 To supply a T360 Series fixture with power insert the Eutrac Multi Adapter 18 into a Eutrac system The fixture s OLED Display 17 will turn on once it is receiving power The On Off Button 13 can toggle the fixture s output on and off Settings can still be adjusted while the switch is set to off Adjusting the Position Use the Yoke Knobs 2 to lock the fixture s ...

Page 3: ... track with a Data Bus The locking and channel knobs lay perpendicular to the track Adjusting the Settings Turn the knobs to adjust CCT Hue and Intensity 1 Barndoor Brackets 2 Yoke Knob 3 Barndoor Lock 4 Magnetic Accessory Lock 5 Side Vents 6 Power Module Box 7 5 Fresnel Zoom Lens T365 only 8 Lens Tighten Knobs T365 only 9 Barndoor Brackets T365 only 10 Barndoor Lock T365 only 11 Light Intensity D...

Page 4: ...e consecutive DMX channels for operation For example with a base DMX address of 50 the controls for intensity CCT and hue will correspond to DMX channels 50 51 and 52 respectively Toadjustthe fixture s DMX address via RDM consult operating instructions for DMX RDM control systems Specifications CCT Range Light Engine Power Draw DC Input AC Input Weight Mount Thermal Design Operating Temperature IP...

Page 5: ...nit or parts The package must be clearly and prominently marked to indicate that the package contains returned product units or parts with a Return Authorization RA number All returned product units or parts must be accompanied by a written explanation of the alleged problem or malfunction 1689 Regatta Blvd Richmond CA 94804 510 620 5155 fiil ex fiilex com www fiilex com Safety Read all instructio...