EN 300 328
2ALHR005
IC: Industry Canada
22518-BT005
Regulatory Compliance Mark
Waste Electrical and
Electronic Equipment
Restriction of Hazardous
Substances Compliant
39
38
Deep Vacuum
Sensor Type:
Thermistor
Port Type:
(1) 3/8” and (3) 1/4” standard NPT male flare fittings
Range and Units:
50 to 9999 microns of mercury (English),
6 to 1330 Pascals (Metric),
0.06 to 13.3 mBar (Metric),
50 to 9999 mTorr (Metric),
0.05 to 10 Torr (Metric, equivalent to mmHg)
Best Resolution:
1 micron of mercury (below 2000 microns),
1 Pascal (below 250 Pascals),
0.001 mBar (below 2.5 mBar),
1 mTorr (below 2000 mTorr),
0.001 Torr (below 2.5 Torr)
Accuracy @ 77°F (25°C):
±(5% of r 5 microns of mercury), 50 to 1000 microns
±(5% of r 1 Pascal), 7 to 133 Pascal
±(5% of r 0.01 mBar), 0.067 to 1.33 mBar
±(5% of r 5 mTorr), 50 to 1000 mTorr
±(5% of r 0.005 Torr), 0.067 to 1 Torr
Wireless Compatibility
Latest compatibility at www.fieldpiece.com
Job Link System Minimum Device Requirement:
BLE 4.0 devices running iOS 7.1 or Android
TM
Kitkat 4.4
Wireless Measurement Source Assignments:
Suction line temperature: Fieldpiece model JL3PC (set to blue)
Liquid line temperature: Fieldpiece model JL3PC (set to red)
Supply air psychrometer: Fieldpiece model JL3RH (set to blue)
Return air psychrometer: Fieldpiece model JL3RH (set to red)
Refrigerant weight scale: Fieldpiece models SRS3, SRS3P
Manifold Diagram
Low Pressure Sensor
High Pressure Sensor
Deep Vacuum Sensor
LOW
Port
LOW
Valve
HIGH
Valve
VAC
Valve
REF
Valve
VAC
Port
REF
Port
HIGH
Port
Compliance