MicroAmps DC (µADC)

Microamps for flame rectifier diode test on a heater control.   

Connect leads between flame sensor probe and control module and 

turn heating unit on to read µA measurement. When the flame is on, 

there should be a measurable µADC signal, typically under 10µADC. 

Compare measurement to manufacturer’s specification to determine 

if replacement is necessary.

Ranges:

  500µA  

Resolution:

  0.1µA  

Accuracy:

  ±(1.0% + 2)    

Volts burden:

 1V 

Overload Protection:

  600VDC or 600VAC rms  

Frequency (Hz) Through Leads

Check incoming voltages to ensure they are cycling at 60Hz.  For 

frequency measurements on VFD equipment, use the amp clamp.

Ranges:

  500Hz, 5kHz, 50kHz, 500kHz, 1MHz  

Resolution:

  0.1Hz

Accuracy:

  ±(0.1% + 5)  

Sensitivity: 

10Hz to 1MHz: >3.5Vrms

PW:

 >1µs  

Duty Cycle Limits:

  >30% and <70%

Duty Cycle (%)

Duty cycle shows the % On Time of a 5V logic signal square wave.

Ranges:

 5%-95% (40Hz to 10kHz), 10%-90% (10kHz to 20kHz)

Accuracy (5V logic):

 ±(2% + 10)  

Resolution:

  0.1%   

PW: 

>10µs

Overload Protection:

  600VDC or 600VAC rms

Capacitance (MFD)

Set to MFD to test motor start and run capacitors.  Capacitors 

are one of the most failure prone components in a HVACR system. 

Disconnect from power and resistors between terminals. Discharge 

capacitor before testing.  If dIS.C is displayed, capacitor is not 

discharged completely. 

Ranges:

  5µF, 50µF, 500µF, 5mF  

Resolution:

  1nF

Accuracy:

  ±(3% + 15) 5µF, ±(3% + 5) 50µF to 500µF,  ±(5% + 20) 5mF

Overload Protection:

  600VDC or 600VAC rms

Voltage DC (VDC)

Select VDC and measure DC voltages on circuit boards on more 

advanced HVACR systems.

 

Ranges:

  500mV, 5V, 50V, 500V, 600V  

Resolution:

  0.1mV  

Accuracy:

  ±(0.5% + 2)

Input impedance:

  >100MΩ (500mV), 10MΩ (5V),  

9.1MΩ (50V-600V)

Resistance (Ω)

Used for “ohming out” a compressor motor.  0.1Ω resolution is 

useful to test the resistance between the motor poles because the 

values are typically very low.   

Ranges:

  500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 50MΩ    

Resolution:

 0.1Ω 

Overload Protection:

  600VDC or 600VAC rms

Accuracy:

  ±(1.0% + 5) 500Ω to 500kΩ,  ±(1.5% + 5) 5MΩ, ±(3.0% 

+ 5) 50MΩ

Continuity  (

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V 

MAX

SEL

HOLD

INRUSH

)

Use the continuity feature to test if a circuit is open or closed.  Use 

this feature to check fuses as well.  A steady “beep” and green LED 

indicate you have continuity. 

Range:

 500Ω  

Resolution:

 0.1Ω  

Response time:

 100ms

Audible beep:

 <30Ω 

Overload Protection:

 600VDC or 600VAC rms

Diode Test  (

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V 

MAX

SEL

HOLD

INRUSH

)

Test diodes for proper forward and reversed-biased functions. 

Test current: 

0.8mA (Approx.)

 

Accuracy: 

±(1.5% + 5)

Open circuit volts

:  3.2VDC typical  

Audible beep

:  <0.03V

Visual Indicator

:  Green LED

Overload Protection:

 600VDC or 600VAC rms

Amps AC (AAC) True RMS

Test any isolated power line.  Press SELECT on VAC/AAC/Hz 

position. Read AAC in upper display. True RMS on SC640 only.

Ranges:

  50A, 400A  

Resolution:

  0.01A 

Crest factor:

  ≤ 3

Accuracy:

  ±(2.0% + 10) 50-60Hz  

Jaw Opening: 

1.2in  

(

30 mm)

Frequency (Hz) Through Clamp

Measure Hz on variable frequency drive motors. Turn dial to VAC/

AAC/Hz and press SELECT twice. Hz will show in upper display. 

Range:

  10Hz to 400Hz  

Accuracy:

  ±(0.1% + 5)

Minimum current range: 

 > 5AAC

 Overload Protection: 

400AAC

Resolution:

  0.1Hz

Inrush Current (SC640 only)

Inrush feature captures starting current of a compressor motor. 

Starting current can assist in diagnosing a motor before it fails.

To activate Inrush feature

1. Turn selector switch to VAC/50AAC/Hz or VAC/400AAC/Hz

2. Press SELECT to show AAC on upper display. Press INRUSH, on right

side of the meter,  to activate.

3. Clamp meter around compressor start wire. Turn motor on. The 

starting current will hold on the upper display. 

4. Hold INRUSH for 2 seconds to exit Inrush feature or press and 

release INRUSH to measure starting current again.

Inrush measurement period:

  100-milliseconds

Minimum input:

 >2A on 50A range; >20A on 400A range

!

  Note:  AAC through the clamp and voltage through the test 

leads can be measured simultaneously. However, if only AAC, 

Frequency (Hz), or Inrush is measured through the clamp, test 
leads and thermcouple must be unplugged from the meter.

Modular 

Expandability

Your new Swivel Clamp Meter is compatible 

with all Fieldpiece Accessory Heads. With 

Fieldpiece Accessory Heads,  you can measure 

any available parameter, and read the 

measurement on your new meter's display in 

real-time. 

Just set the range to VDC and press the 

RANGE button until mV is displayed.  Remove 

the probe tips of your test leads, and connect 

your accessory head (model AAV3 shown). 

Visit www.

testequipmentdepot

.com to 

see all of the different accessory heads that 

Fieldpiece offers. 

Temp. Calibration

For accuracies of ±1°F, calibrate thermocouple 

to a known temperature.  A glass of stabilized 

ice water is very close to 32°F (0°C) and is usually 

very convenient but any known temperature 

can be used. 

1. Select the °F °C range.

2. Plug thermocouple to be 

calibrated into the Type K 

jack.

3. Unscrew A and B and 

remove the battery cover.

4. Stabilize a large cup of ice 

water. Stir the ice with the 

water until temperature 

stays at a stable value.

5. Immerse the thermocouple 

probe and let it stabilize. 

Keep stirring water to 

prevent thermocouple from 

direct contact with ice.

6. Use a small screwdriver 

to adjust calibration pot C 

below the battery as close to 

32°F(0°C) as you would like.

Note:  J1-J2 switch is for auto-

calibration purposes only. Do 

not switch from J2.

Auto Power Off

Auto power off or APO will automatcially turn 

off your meter after 30 minutes of inactivty. By 

default it is activated and APO will show on the 

display. To disable, turn meter off. Hold 

HOL

D

COM

CAT III

600V

Fieldpiece

Select

Range

M/m

SC240

V

AC

NCV

A

AC

°F°C

V

DC

MFD

TEMP

AUTO OFF

TYPE K

30V

MAX

 and 

power on the meter by turning the selector dial 

to any range. Release 

HOL

D

COM

CAT III

600V

Fieldpiece

Select

Range

M/m

SC240

V

AC

NCV

A

AC

°F°C

V

DC

MFD

TEMP

AUTO OFF

TYPE K

30V

MAX

 after the beep. APO will 

no longer display over the battery icon.

Auto Hold

Press and hold

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F

°C

H

Z

SC640

AUTO OFF

TYPE K

30V

MAX

Select

Range

Hold

INRUSH

COM

TRUE RMS

for two seconds. Meter 

will beep and HOLD will blink on LCD. After 6 

seconds the measurement on screen will freeze 

automatically. Press

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F

°C

H

Z

SC640

AUTO OFF

TYPE K

30V

MAX

Select

Range

Hold

INRUSH

COM

TRUE RMS

 to exit this mode. 

Battery Replacement

When your meter’s battery is low, the battery 

icon will appear empty and blink for 30 seconds. 

“LO.bt” will display and meter will power off. 

Turn dial to OFF position, disconnect test 

leads and remove the battery cover with magnet 

strap on the back of your meter. Remove old 

battery and replace with a standard 9V battery 

only. Be sure to re-insert the magnet strip before 

re-installing the battery cover.

Maintenance

Clean the exterior with a dry cloth.  Do not 

use liquid.

Limited Warranty

This meter is warranted against defects in 

material or workmanship for one year from 

date of purchase. Fieldpiece will replace or 

repair the defective unit, at its option, subject 

to verification of the defect.

This warranty does not apply to defects 

resulting from abuse, neglect, accident, 

unauthorized repair, alteration, or unreasonable 

use of the instrument.

Any implied warranties arising from the sale of 

a Fieldpiece product, including but not limited 

to implied warranties of merchantability and 

fitness for a particular purpose, are limited to 

the above. Fieldpiece shall not be liable for loss 

of use of the instrument or other incidental or 

consequential damages, expenses, or economic 

loss, or for any claim of such damage, expenses, 

or economic loss. 

State laws vary. The above limitations or 

exclusions may not apply to you.

Obtaining Service

Call Fieldpiece Instruments for one-price-

fix-all out-of-warranty service pricing. Send 

check or money order for the amount quoted. 

Send the meter freight prepaid to Fieldpiece 

Instruments. Send proof of date and location 

of purchase for in-warranty service. The meter 

will be repaired or replaced, at the option 

of Fieldpiece, and returned via least cost 

transportation.

For international customers, warranty for 

products purchased outside of the U.S. should 

be handled through local distributors.

© Fieldpiece Instruments, Inc  2014;  v28

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

O

FF

VA

C

VA

C

%

N

CV

V

DC

µA

DC

M

FD

H

Z

A

AC

50

H

Z

A

AC

40

0

°F   °

C

H

Z

SC640

AUT

O OFF

TY

PE

 K

30

V

M

AX

Se

le

ct

Ra

ng

e

Ho

ld

INR

USH

CO

M

TR

UE

 R

M

S

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

Discharge Cap First!

OFF

VAC

VAC

%

NCV

VDC

µADC

MFD

HZ

AAC

50

HZ

AAC

400

°F 

°C

HZ

SC640

AUTO OFF

K-TYPE

30V

MAX

Select

Range

Hold

IN

R

U

S

H

COM

TRUE RMS

OFF

V

AC

V

AC

%

NCV

V

DC

µA

DC

MFD

H

Z

A

AC

50

H

Z

A

AC

400

°F 

°C

H

Z

Air Velocity

& Temperature

Head

English

READ

LO BATT

ON

LCD X

100

Average

(16 sec)

Metric

Real

time

AAV3

AUTO-

OFF

English

Metric

Ft/min

M/s

KM/hr

MPH

ºF

ºC

OFF

A

B

C

TEMP

 CAL

DO NOT SWITCH

FROM J2

T1

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Reviews: